Service Manual

Reelmaster 3100−D
Page 4 − 65
Hydraulic Tank Removal
1. Drain hydraulic tank (see Change Hydraulic Fluid).
2. Remove hydraulic tank from machine using Figures
40 and 41 as guides.
Hydraulic Tank Inspection
1. Clean hydraulic tank and suction strainer with sol-
vent.
2. Inspect hydraulic tank for leaks, cracks, or other
damage.
Hydraulic Tank Installation
1. On early production machines, assemble suction
strainer and fitting:
NOTE: When applying hydraulic thread sealant to the
threads of fitting and the suction strainer, do not apply
sealant to the first thread.
A. Apply hydraulic thread sealant to the threads of
the hydraulic fitting (suction). Secure fitting to the
suction strainer.
B. Apply hydraulic thread sealant to the threads of
the suction strainer.
2. Apply anti−seize lubricant to four flange head
screws. Secure hydraulic tank to machine with flange
head screws. Torque flange head screws from 30 to 60
in−lb (3.4 to 6.8 N−m).
3. Using a wrench, turn suction strainer into tank port at
least 1−1/2 to 2 full turns beyond finger tight.
4. Complete hydraulic tank installation using Figures
40 and 41 as guides.
1. Gear pump 2. Suction hose
Figure 41
1
2
Hydraulic
System
Hydraulic System