User Manual

INSTALLATION INSTRUCTIONS
SPECIFICATIONS
Model: TGT02
7-DAY PROGRAMMABLE
HEAVY DUTY DIGITAL PLUG-IN TIMER
FEATURES
LED..............…..…….................……..........................…...........…...................................150W
Turn the Load ON/OFF and switch between Automatic and Manual modes by pressing the
MODE button.
The large and easy-to-read LCD screen displays the current day of week, time, Auto/
Manual mode, whether the Load is ON or OFF, and the program settings.
The Timer can be programmed up to 18 ON and 18 OFF settings.
Random feature (RND) turns ON/OFF the Load at a random time, 30 minutes within the
programmed time.
DST: Daylight Savings Time
Motor…….....…..…….................……..........................…...........…..................................1/2HP
Voltage …………………………………….........…...........…..…….................….. 120VAC, 60Hz
Resistive………..........…...…….…………..…...........…......................................15Amp, 1800W
Tungsten..............................................................…...........….........................................1200W
Flourescent.............................................................…...........…....................................1200VA
WARRANTY
This device is warranted to be free of material and workmanship defects for 1 year from the date of purchase. Original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL claims must be verified
and approved by Top Greener, Inc. Warranties from other Top Greener products may vary. This warranty is nontransferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect,
alteration, modification, or improper installation. To the fullest extent permitted by the applicable state law, Top Greener shall not be liable to the purchaser or end user customer of Top Greener products for direct, indirect, incidental, or
consequential damages even if Top Greener has been advised of the possibility of such damages. Top Greener’ total liability under this or any other warranty, express or implied, is limited to repair, replacement or refund. Repair, replacement
or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.
© 2016 TOPGREENER, Inc. ● CA, U.S.A. ● WWW.TOPGREENER.COM ● 0204170086-03
MODE/RCL
PGM MAN
DAY HOUR MIN
DST
R
RND
BUTTONS AND INDICATORS
1.
Indicates the day(s) of the week.
Options are:
MO = MONDAY
TU = TUESDAY
WE = WEDNESDAY
TH = THURSDAY
FR = FRIDAY
2. DAYLIGHT SAVINGS TIME indicator DST displayed = ON DST no displayed = OFF
3. Indicates the status of connect light(s) or load(s): ON/ OFF
4. DAY button. Select day(s) of the week: SPECIFIC DAY OF EACH WEEK,
WEEKDAYS, WEEKENDS, EVERYDAY
5. HOUR button. During programming, it’s used to select the hour: 1 thru 12 AM/ PM At
the main screen, it’s used to turn Daylight Savings ON/ OFF
6. AUTO/ MANUAL indicator. Indicates Manual operation mode and Automatic timer
controlled mode
7. MINUTES/ RANDOM MODE button. During programming, it’s used to change the
minutes. At the main screen, it’s used to turn Random Mode ON/ OFF
8. RESET button: Push to reset all settings to Factory Default
9. PROGRAMMING button. Press once to enter the Programming of the Clock. Press
twice to enter the Programming of the schedule
10. MANUAL button. It’s used to manually turn the light(s)/ load(s) ON/ OFF
11. MODE/ RECALL button. During programming, it’s used as a Recall button:
Press RCL to bypass or Recall a saved program At the main screen, press the
MODE button to switch between Manual operation mode and Automatic timer
controlled mode
12. AM/ PM indicator
13. CLOCK
14. RANDOM mode indicator
RND displayed = ON RND not displayed = OFF
SA = SATURDAY
SU = SUNDAY
MO TU WE TH FR = WEEKDAYS
SA SU = WEEKENDS
MO TU WE TH FR SA SU = ALL DAYS OF WEEK
PROGRAMMING
NOTE:
This Timer has a built in rechargeable battery backup. The programming will be
stored during the event of a power outage.
In programming mode, there is a 12 seconds time-out. If no buttons are
pressed within 12 seconds, the display will return to main screen.
The switch displays the time in 12-hour format.
To Enter Programming Mode
1. Press the PGM (Program) button once to set the clock (the current time).
2. Press the PGM (Program) button two times to enter the programming mode
for adding and removing ON or OFF times on the schedule.
At any point during programming of the clock or schedule, the MAN (Manual)
button may be pressed to exit and return to the main screen.
Setting the Current Time and Day (CLOCK)
1. Press the PGM button once and the CLK icon will appear on the bottom left of
the screen.
2. Set the time using the HOUR and MIN buttons. Make sure the AM/PM indicator
is displaying the right letter.
3. Select the current day of the week by using the DAY button.
4. Press the MAN button to return to the main screen.
Adding ON and OFF times to the schedule
NOTE: Each program you add to the schedule should have an "ON" and an "OFF"
time. The day(s) you select for the "ON" time should match the day(s) in the
"OFF" time.
1. From the main screen, press the PGM button two times and "1ON PROG" will
appear on the screen. You are now ready to set the ON time for PROGRAM 1.
2. Set the time using the HOUR and MIN buttons. Make sure the AM/PM indicator
is displaying the correct letter.
3. Select the day of the week by using the DAY button.
NOTE: if you want to apply the program to every day of the week,
press the DAY button until all the days of the week are displayed. This
will count as 1 program, not 7 separate programs.
4. Once the day is selected, press the PGM button once and "1OFF PROG" will
appear on the screen. You are now ready to set the OFF time for PROGRAM 1.
Repeat steps 2 and 3 to set the OFF time and day.
5. Once you are done selecting the OFF time and day, press the MAN button to
return to the main screen or the PGM button add more programs to the
schedule.
BYPASS a Program:
1.
Press PGM button to scroll through the programs and stop when you see the
ON or OFF program that you wish to bypass
.
2.
Press the MODE/RCL button. When you see "--:--", the program will be
bypassed. Remember to bypass each OFF program for every ON program
and vice versa.
3.
When you are done bypassing the programs, press the MAN button to return
to the main screen.
Reseting the Timer:
To reset the Timer back to Factory Default Settings, use a small object such as
paper clip or the tip of a pen and press and release the "R" button. The display
will flash indicating a reset.
Run the Program: See OPERATING THE TIMER on next page.