Use and Care Manual

Maintenance
10
Section 4 Maintenance
4.1 Replacing UV Lamp
Lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000
hours of continuous operation (approximately one year) in order to ensure adequate disinfection.
Procedure:
WARNING
Always disconnect power before performing any work on the disinfection system.
Always shut-off water flow and release water pressure before servicing.
Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present.
Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection.
Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.
NOTICE
Reset lamp life timer after lamp replacement. Refer to Section 5.1.3. Refer to www.lamprecycle.org for lamp disposal.
Do not use water during replacement of UV lamp.
1
Shut off the water line to
chamber and release system
pressure before servicing.
2
0
30
15
45
10 mins
Disconnect main power
source and allow the unit to
cool for 10 minutes.
3
1
2
Remove the lamp connector
by squeezing the plastic
locking tabs on the side of the
connector.
4
Hg
UV
Remove the lamp in upward
direction from the chamber
and lamp connector base.
Always hold the lamp at the
ceramic ends.
5
Hg
UV
1
2
Insert the new lamp fully into
the chamber leaving about
two inches of the lamp
protruding from the chamber.
6
4
2
3
1
Attach the connector to the
lamp and note that the
connector will only allow
correct installation in one
position.
7
1
2
click
Push the lamp connector
against lamp connector base
together until an audible click
is heard.
Re-pressurize the system to
check for leaks.
8
Hold down the timer reset
button and reapply power to
the controller until you see
, then release timer
reset button.
A 5 second delay will occur
until you hear an audible tone
and LED display will read
once again .