Home Filtration Systems OWNERS MANUAL
Table of Contents SYSTEM PAGE Carbon System with KDF 1-6 Salt Free Softener 7-11 Replacement Components 12
Carbon Series 1 BEFORE YOU BEGIN INSTALLATION, READ THIS ENTIRE MANUAL. FOLLOW THE INSTALLATION INSTRUCTIONS CAREFULLY. 1. Avoid pinched o-rings during installation by applying NSF certified lubricant to all seals. 2. This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
UNPACKING / INSPECTION Be sure to check the entire unit for any shipping damage or parts loss. Also note damage to the shipping cartons. Small parts needed to install the filter are in a parts box. To avoid loss of the small parts keep them in the parts bag until you are ready to use them.
SAFETY GUIDE For your safety the information in this manual must be followed to minimize the risk of electric shock, property damage or personal injury. Check and comply with your provincial / state and local codes. You must follow these guidelines. Use care when handling the filter tank. Do not turn upside down, drop, drag or set on sharp protrusions. PROPER INSTALLATION This system must be properly installed and located in accordance with the installation instructions before it is used.
SPECIFICATIONS HowYour Filter Works Please review operating pressures, temperatures and water chemistry limitations to ensure compatibility. System Specifications Service Flow Rates 8000 10000 5 gpm 7gpm Filter Media Volume - Cubic Feet 75 ft 1.
WHERE TO INSTALL Place the filter tank as close as possible to the pressure tank (well system) or water meter (city water). Connect the filter to the main water supply pipe BEFORE the water heater. DO NOT RUN HOT WATER THROUGH THE FILTER. Temperature of water passing through the filter must be less than 100 deg F. Keep the filter out of direct sunlight. The suns heat may soften and distort plastic parts. Do not install the filter in a place where it could freeze. Water freezing may damage the system.
TROUBLE SHOOTING A. FILTER BLEEDS TASTE AND ODOR OR SEDIMENT B. LOW WATER PRESSURE Question Answer 1. By-pass valve open. Close by-pass valve. 2. Defective or stripped media bed Replace media 3. Quality of water has worsened Have water sample analyzed to determine any change 4. Filter capacity too small Replace with larger unit or add another filter 5. Leak between valve and central tube. Check if central tube is cracked or o-ring is damaged. Replace faulty parts. 6. Internal valve leak.
Salt-Free Softener 7 BEFORE YOU BEGIN INSTALLATION, READ THIS ENTIRE MANUAL. FOLLOW THE INSTALLATION INSTRUCTIONS CAREFULLY. 1. Avoid pinched o-rings during installation by applying NSF certified lubricant to all seals. 2. This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
SAFETY GUIDE For your safety, the information in this manual must be followed to minimize the risk of electric shock, property damage or personal injury. Check and comply with your provincial / state and local codes. You must follow these guidelines. Use care when handling the filter tank. Do not turn upside down, drop, drag or set on sharp protrusions. PROPER INSTALLATION This system must be properly installed and located in accordance with the installation instructions before it is used.
SPECIFICATIONS How Your Filter Works Please review operating pressures, temperatures and water chemistry limitations to ensure compatibility. System Specifications Service Flow Rates Filter Media Volume - Cubic Feet Filter Tank Size Media Type 8000 10000 5gpm 7 gpm 75ft 1.
WHERE TO INSTALL Place the filter tank as close as possible to the pressure tank (well system or water meter (city water. Connect the filter to the main water supply pipe BEFORE the water heater. DO NOT RUN HOT WATER THROUGH THE FILTER. Temperature of water passing through the filter must be less than 100 deg. F. Keep the filter out of direct sunlight. The suns heat may soften and distort plastic parts. Do not install the filter in a place where it could freeze. Water freezing may damage the system.
TROUBLE SHOOTING A. FILTER BLEEDS TASTE AND ODOR OR SEDIMENT B. LOW WATER PRESSURE Question Answer 1. By-pass valve open. Close by-pass valve. 2. Defective or stripped media bed Replace media 3. Quality of water has worsened Have water sample analyzed to determine any change 4. Filter capacity too small Replace with larger unit or add another filter 5. Leak between valve and central tube. Check if central tube is cracked or o-ring is damaged. Replace faulty parts. 6. Internal valve leak.
ORDER REPLACEMENT COMPONENTS OR ADDITIONAL INSTALLATION PARTS Replacement Components Tier1 makes it easy to order replacement components. Simply visit the URL below to order the replacement component you need. Component: Order Online at: Series 8000 Replacement Pre-filter Kit www.tier1filters.com/8000-fhr Series 8000 Replacement UV bulb www.tier1filters.com/8000-bulb Series 8000 Salt Free Softener Replacement Media Kit www.tier1filters.com/8000-sf-rmk Series 10000 Replacement Pre-filter Kit www.