Cut Sheet
Table Of Contents
- T&B Fitting
- Product Overview
- Rigid & Intermediate Metal Conduit Fittings
- Form 7, Form 8, Series 35, Conduit Outlet Bodies & Covers
- Mogul Conduit Outlet Bodies
- FS/FD Cast Device Boxes and Covers
- Conduit Outlet Boxes
- Conduit Outlet Elbows, Reducers, Plugs, and Adapters
- Three-Piece Couplings
- Sealing Fittings
- Kopr-Shield Compound
- Jacketed Metal Clad Cable Termination Fittings
- Tray Cable Fittings
- EMT Fittings
- Liquidtight Flexible Metal Conduit Fittings
- Shureflex™ Nylon Conduit System
- XTRA FLEX System
- Flexible Cord and Cable Fittings
- Flexible Cord and Cable Fittings - Non-Metallic
- Service Entrance Cable Fittings
- Metal Clad Cable, Armored Cable and FlexibleMetal Conduit Fittings
- Non-Metallic Sheathed Cable Fittings
- Conduit Dimensional Data
Rigid and Intermediate Metal Conduit Fittings
UL Listed raintight and CSA Certified watertight and dusttight.
Steel/Malleable Iron and Aluminum Bullet
®
Hub Connectors*
†
CAT. NO.
HUB MAX. WALL
STEEL/ STEEL/M.I. SIZE DIMENSIONS (IN.) THICKNESS
M.I. ALUM.** W/LOCKNUT (IN.) A B C (IN.)
370 370AL 401
1
⁄2"1
3
⁄8 1
1
⁄4
3
⁄4
5
⁄16
371 371AL 402
3
⁄4 1
5
⁄8 1
1
⁄4
3
⁄4
5
⁄16
372 372AL 403 1" 2
3
⁄32 1
3
⁄8
7
⁄8
5
⁄16
373 373AL 404-TB 1
1
⁄8"2
9
⁄16 1
5
⁄8 1
5
⁄16
374 374AL 405 1
1
⁄2"3
3
⁄32 1
5
⁄8 1
5
⁄16
375 375AL 406-TB 2" 3
5
⁄8 1
5
⁄8 1
5
⁄16
376 — 407 2
1
⁄2"4
1
⁄8 1
7
⁄8 1
1
⁄8
3
⁄8
377 — 408 3" 5 2
1
⁄2 1
1
⁄2
1
⁄2
378 — 409 3
1
⁄2"5
9
⁄16 2
1
⁄2 1
1
⁄2
1
⁄2
379 — 410-TB 4" 6
3
⁄16 2
1
⁄2 1
1
⁄2
1
⁄2
381 — — 5" 8 3
1
⁄8
1
⁄2
382 — — 6" 9
3
⁄16 3
1
⁄8
1
⁄2
*
Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 2; Class III, Div. 1 and 2
where general purpose equipment is specifically permitted per NEC Section 500-2(a).
**
Aluminum not available with insulated throat.
†
UL Listed rain tight and CSA Certified watertight and dust tight
Available with DURA-PLATE
®
finish.
UL File No. E-23018
For Stl.: CSA File No. 2284
For AL.: CSA File No. 0637
Spacing Chart for Bullet
®
Hubs
MIN. SPACE FROM
CENTER-TO-CENTER SPACING
CENTER OF KO
CONDUIT SIZES
BULLET
®
HUB TO DIAMETERS
1
⁄2
3
⁄4 11
1
⁄4 1
1
⁄2 22
1
⁄2 33
1
⁄2 4 5 6 WALL OF BOX (MIN.)
1
⁄2 1
7
⁄16 1
5
⁄8 1
3
⁄4 2
1
⁄8 2
3
⁄8 2
5
⁄8 2
7
⁄8 3
5
⁄16 3
1
⁄2 3
7
⁄8 4
7
⁄8 5
5
⁄16
3
⁄4
7
⁄8
3
⁄4 — 1
3
⁄4 1
7
⁄8 2
1
⁄4 2
1
⁄2 2
3
⁄4 33
1
⁄2 3
3
⁄4 4
1
⁄8 4
13
⁄16 5
1
⁄2
7
⁄8 1
1
⁄8
1— — 2 2
3
⁄8 2
5
⁄8 2
7
⁄8 3
1
⁄8 3
5
⁄8 3
7
⁄8 4
1
⁄4 4
15
⁄16 5
11
⁄16 1
1
⁄8 1
3
⁄8
1
1
⁄4 — — — 2
11
⁄16 2
15
⁄16 3
1
⁄4 3
1
⁄2 44
1
⁄4 4
1
⁄2 5
5
⁄16 5
3
⁄4 1
3
⁄8 1
3
⁄4
1
1
⁄2 — — — — 3
1
⁄8 3
1
⁄2 3
3
⁄4 4
1
⁄8 4
3
⁄8 4
3
⁄4 7
7
⁄16 6
3
⁄16 1
5
⁄8 2
2 — — — — — 3
3
⁄4 44
1
⁄2 4
3
⁄4 55
3
⁄4 6
1
⁄2 1
7
⁄8 2
1
⁄2
2
1
⁄2 — — — — — — 4
1
⁄4 4
3
⁄4 55
3
⁄8 66
3
⁄4 2
1
⁄8 3
3 — — — — — — — 5
1
⁄8 5
3
⁄8 5
3
⁄4 6
3
⁄8 7
1
⁄8 2
5
⁄8 3
5
⁄8
3
1
⁄2 — — — — — — — — 5
5
⁄8 66
3
⁄4 7
1
⁄2 2
7
⁄8 4
1
⁄8
4 — — — — — — — — — 6
1
⁄4 7
1
⁄8 7
7
⁄8 3
1
⁄4 4
5
⁄8
5 — — — — — — — — — — 8 8
3
⁄4 45
1
⁄2
6 — — — — — — — — — — 8
3
⁄4 9
1
⁄2 4
3
⁄4 6
1
⁄2
• Available in steel/malleable iron (steel through 1")
with nylon-insulated throat — with or without
Series 106 bonding locknut
• Also available in aluminum without insulated throat
• When used with neoprene O-ring, provides watertight
threaded hub on enclosures
• UL Listed 105° C
• Look for the unique T&B blue color ensuring
the highest quality fitting
A-16
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com