Cut Sheet
Table Of Contents
- T&B Fitting
- Product Overview
- Rigid & Intermediate Metal Conduit Fittings
- Form 7, Form 8, Series 35, Conduit Outlet Bodies & Covers
- Mogul Conduit Outlet Bodies
- FS/FD Cast Device Boxes and Covers
- Conduit Outlet Boxes
- Conduit Outlet Elbows, Reducers, Plugs, and Adapters
- Three-Piece Couplings
- Sealing Fittings
- Kopr-Shield Compound
- Jacketed Metal Clad Cable Termination Fittings
- Tray Cable Fittings
- EMT Fittings
- Liquidtight Flexible Metal Conduit Fittings
- Shureflex™ Nylon Conduit System
- XTRA FLEX System
- Flexible Cord and Cable Fittings
- Flexible Cord and Cable Fittings - Non-Metallic
- Service Entrance Cable Fittings
- Metal Clad Cable, Armored Cable and FlexibleMetal Conduit Fittings
- Non-Metallic Sheathed Cable Fittings
- Conduit Dimensional Data
Flexible Cord and Cable Fittings
2920 Ranger
®
Series
2920AL Ranger
®
Series
Ranger
®
Series of Liquidtight Flexible Cord and Cable Connectors
Standard Material
Gland, Body . . . . .Steel/Malleable Iron/Zinc
Die Cast
Retaining RingThermoplastic/Stainless Steel
Bushing . . . . . . . . . . . . . . . . . . .Neoprene
O-Ring . . . . . . . . . . . . . . . . . . . . .Buna N
Standard Finish
Electro Zinc Plated & Chromate Coated
Range
2520 Series, straight . . . . .0.125" outside
diameter to 3.200"
outside diameter Cord or Cable
2200 Series, 45° . . . . . . . .0.125" outside
diameter to 1.485"
outside diameter Cord or Cable
2267 Series, 90° . . . . . . . .0.125" outside
diameter to 1.875"
outside diameter Cord or Cable
2900 and 4900 Ranger
®
Series . . .0.250"
cable range
Cord/Cable Type . . . . . . . . . .S, SO, SV, ST,
STO, SJ, SJO, SJT, SJTO, SVO & SVT
Listings/Compliances
UL File No. E-13938
CSA LR-589, LR-4484
UL 514
CSA. 22.2 No. 18
ANSI C33.84, NFPA 70-1978 (ANSI)
SVO, SV, SVT SJ, SJO, SJT, SJTO S, SO, ST, STO
CAT. NO
SIZE MIN. MAX.
#18 #18 #16 #14 #18 #16 #14 #12 #10 #8 #6
2 Conductor
2920
1
⁄2" 0.125 0.375 X X X X
2921
1
⁄2" 0.310 0.560 X X X X X
2922
1
⁄2" 0.500 0.750 X X X X X X
2930
3
⁄4" 0.125 0.375 X X X X
2931
3
⁄4" 0.310 0.560 X X X X X
2932
3
⁄4" 0.500 0.750 X X X X X X
2940 1" 0.310 0.560 X X X X X
2941 1" 0.500 0.750 X X X X X X
2942 1" 0.700 0.950 X X X
3 Conductor
2920
1
⁄2" 0.125 0.375 X X X
2921
1
⁄2" 0.310 0.560 X X X X X
2922
1
⁄2" 0.500 0.750 X X X
2930
3
⁄4" 0.125 0.375 X X X
2931
3
⁄4" 0.310 0.560 X X X X X
2932
3
⁄4" 0.500 0.750 X X X
2940 1" 0.310 0.560 X X X X
2941 1" 0.500 0.750 X X X X
2942 1" 0.700 0.950 XX
4 Conductor
2920
1
⁄2" 0.125 0.375 X
2921
1
⁄2" 0.310 0.560 X X X X X
2922
1
⁄2" 0.500 0.750 X X
2930
3
⁄4" 0.125 0.375 X
2931
3
⁄4" 0.310 0.560 X X X X X
2932
3
⁄4" 0.500 0.750 X X
2940 1" 0.310 0.560 X X X X X
2941 1" 0.500 0.750 X X
2942 1" 0.700 0.950 XX
2516 Series
A-137
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com
2920SST Ranger
®
Series
Application
• A liquidtight connector to connect flexible cord or cable
to an enclosure and provide adequate strain relief
Features
• Liquidtight connection with enclosure is ensured by:
(A)Taper threaded hub on 2520 series for female hub
application
(B)Using sealing ring series 5262 with 2520 series
for knockout application
(C)Captivated sealing O-Ring on 2631 series
(D)Neoprene bushing makes liquidtight installation; applies
pressure against cable the full length of bushing
(E)Thermoplastic or stainless steel retaining ring
(1) Will not abrade cord/cable jacket
(2) Reduces installing torque effort
• UL Listed liquidtight, strain relief and as an outlet bushing;
CSA certified watertight