Cut Sheet
Table Of Contents
- T&B Fitting
- Product Overview
- Rigid & Intermediate Metal Conduit Fittings
- Form 7, Form 8, Series 35, Conduit Outlet Bodies & Covers
- Mogul Conduit Outlet Bodies
- FS/FD Cast Device Boxes and Covers
- Conduit Outlet Boxes
- Conduit Outlet Elbows, Reducers, Plugs, and Adapters
- Three-Piece Couplings
- Sealing Fittings
- Kopr-Shield Compound
- Jacketed Metal Clad Cable Termination Fittings
- Tray Cable Fittings
- EMT Fittings
- Liquidtight Flexible Metal Conduit Fittings
- Shureflex™ Nylon Conduit System
- XTRA FLEX System
- Flexible Cord and Cable Fittings
- Flexible Cord and Cable Fittings - Non-Metallic
- Service Entrance Cable Fittings
- Metal Clad Cable, Armored Cable and FlexibleMetal Conduit Fittings
- Non-Metallic Sheathed Cable Fittings
- Conduit Dimensional Data
Rigid and Intermediate Metal Conduit Fittings
Meets and surpasses NEC
®
requirements!
Insulated Throat Fittings
Locknut-type base improves bonding
and resists loosening under vibration.
• Aluminum, steel or malleable
iron (steel through 1
1
⁄2")
• Smoothly rounded shoulder
covers end of conduit
• Broad flange covers knockout hole
• High ribs for easy tightening with fingers
or with wrench
•
1
⁄2" to 1
1
⁄2" sizes, formed in steel, feature
extra-smooth shoulders
Metallic Bushings
Perfect threads for easy thread-on!
• Impact-resistant plastic insulation
• Ribbed for easy, secure gripping
• UL Listed 105° C
Plastic Insulating Bushings
All Plastic Insulating
Bushings
CAT. NO.
DIMENSIONS (IN.)
STL. OR M.I. ALUM. SIZE A B
122 122AL
1
⁄2"1
1
⁄32
13
⁄32
123 123AL*
3
⁄4"1
1
⁄4
7
⁄16
124 124AL** 1" 1
9
⁄16
1
⁄2
125-TB 125AL 1
1
⁄4"1
29
⁄32
9
⁄16
126 126AL 1
1
⁄2"2
5
⁄32
19
⁄32
127 127AL 2" 2
21
⁄32
5
⁄8
128 128AL 2
1
⁄2"3
3
⁄16
3
⁄4
129 129AL 3" 3
27
⁄32
13
⁄16
130-TB 130AL 3
1
⁄2"4
3
⁄8
15
⁄16
131-TB 131AL 4" 4
15
⁄16 1
132-TB — 4
1
⁄2"5
7
⁄16 1
5
⁄64
133-TB 133AL 5" 6 1
3
⁄16
134-TB 134AL 6" 7
1
⁄4 1
1
⁄4
CAT. NO.
DIMENSIONS (IN.)
STL. OR M.I. ALUM. SIZE A B
1222 1222AL
1
⁄2"1
1
⁄32
29
⁄64
1223 1223AL
3
⁄4"1
9
⁄32
31
⁄64
1224 1224AL 1" 1
19
⁄32
11
⁄32
1225 1225AL 1
1
⁄4"1
15
⁄16
21
⁄32
1226 1226AL 1
1
⁄2"2
3
⁄16
23
⁄32
1227 1227AL 2" 2
11
⁄16
7
⁄8
1228 1228AL 2
1
⁄2"3
3
⁄16
1
⁄32
1229 1229AL 3" 3
27
⁄32
5
⁄16
1230 1230AL 3
1
⁄2"4
7
⁄16 1
1
⁄16
1231 1231AL 4" 4
7
⁄8 1
3
⁄32
1232
†
1232AL
†
4
1
⁄2"— —
586 586AL 5" 5
31
⁄32 1
9
⁄32
587 587AL 6" 7
3
⁄16 1
11
⁄32
†
Not CSA Certified
Catalog series 1222 thru 1232, 586 and 587 are available in aluminum. Add suffix
AL to Cat. No. The aluminum series fittings are not CSA certified.
*
Not UL Listed or CSA Certified
**
Not CSA Certified
Available with DURA-PLATE
®
Finish.
UL File No. E-23018
CSA File No. 2884
DIMENSIONS (IN.)
CAT. NO.
SIZE A B
222-TB
1
⁄2"1
1
⁄16
3
⁄8
223-TB
3
⁄4"1
9
⁄32
13
⁄32
224 1" 1
9
⁄16
9
⁄16
225-TB 1
1
⁄4"1
29
⁄32
9
⁄16
226 1
1
⁄2"2
7
⁄32
9
⁄16
227 2" 2
25
⁄32
5
⁄8
228-TB 2
1
⁄2"3
3
⁄8
3
⁄4
229-TB 3" 4
1
⁄16
3
⁄4
230-TB 3
1
⁄2"4
5
⁄8
7
⁄8
231 4" 5
1
⁄8
7
⁄8
232 4
1
⁄2"5
11
⁄16 1
233 5" 6
5
⁄16 1
234 6" 7
7
⁄16 1
UL Rated flame retardant 94V-1
Nylon insulated
metallic bushings
•
Steel or malleable iron (steel through 1
1
⁄2")
• Exceeds NEC 373-6C requirements
for protection of ungrounded
connectors at entrance to raceways,
pull boxes and junctions
• Recognizable by distinctive trademarked
blue insulating liner in throat
• Reduces wire pulling effort
by as much as 50%
• Temperature rating of 105° C
• Look for the unique T&B blue color,
ensuring the highest quality fitting
A-10
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com