Installation Sheet

THESE STEPS MUST BE TAKEN FOR CORRECT INSTALLATION OF THE CONTROL. REMOVE MUD RING
FROM WALL CUTOUT BEFORE MAKING FINAL CABLE CONNECTIONS TO THE THERMATOUCH CONTROL.
TEST THAT ALL CONNECTIONS ARE WORKING BEFORE SEALING THE CONTROL TO THE WALL.
(Power on the control and see that it lights up).
Coat the entire groove on the control back with supplied waterproof silicone to fully seal the control to the wall.
Completely seal the control to the wall so moisture does not collect behind it.
Place the control on the wall pressing rmly.
(You may need to tape the control into place until the silicone dries.)
Be careful not to harm the wall or control with the tape. Let dry for 24 hours before using steam bath.
A
5 Sealing Control
Side View of Surface
Mount Control
Back Side of Surface
Mount Control
THERMASOL.COM
I
800.776.0711
SILICONE
A
Wall
M12 Cable Connection
Ethernet Cable
Connection
Audio Cable
Connection
Wall
Wall
66
Total Wellness Package