Installation Sheet

Shower wall
Route the M12 cable through the nished wall
to the back side of the control. (The other end
of the cable runs to the PDM location.) NOTE:
It is recommended to run the cable through
electrical conduit. DO NOT STAPLE the cable!
Run the M12 cable so the 90-degree end
connection will connect to the ThermaTouch
control. Then connect the M12 Cable to
ThermaTouch control. Do not over tighten.
If the Serenity Light, Sound, Rain Head option is
not used then amplied speakers are required
for sound.
Connect the data cable to Power Distribution Module (PDM).
(The other end of the cable runs to the back of the control in the shower location.)
DO NOT pinch, nail, staple, wedge, or bind the
data cable.
DO NOT wrap the data cable around steam line
or route it in a manner so that the hot steam line
could melt
the cable.
Any damage to the control cable will result in
the control not working properly.
Carefully connect the data cable to the PDM
and control BEFORE turning power on to the
generator or PDM.
"ON"
Turn Clockwise
"OFF"
Turn Counter Clockwise
• Do not staple, strain or damage data cable
• Align pins to receptacle visually before tightening
• Do not force plug
• Hand tighten only
Connector
Detail
Contact
pins
TTC
SLS
Connect to PDM
PDM requires 110V power
Contact
pins
Cable
ends
RCA cable included with control
M12 Cable
Ethernet cable with RJ-45
(not included)
THERMASOL.COM
I
800.776.0711
4 Control Installation and Data Cable Connection
5
Total Wellness Package