Installation Sheet

Steamhead Location
Steamhead rough-in tting
to be installed ush and
sealed to nished wall
C
C
Insert protective cap
into housing
Insert installation tool and
tighten housing into place
with a 1" socket and driver
DO NOT install the steamhead near the seating area or the user.
DO NOT forget to install the steamhead rough-in tting!
Install the steamhead 24" from the oor or bathtub rim
and 6" from any corner.
Steamhead is to be mounted as far as possible from
typical bathing position (seated or standing) and installed
as far from the in-shower controller as possible.
For retrot to existing nish wall:
Drill a 1-1/8" diameter hole in the shower wall or wall above
bathtub rim for the steam outlet rough-in tting and install
to be ush with the nished wall. this housing must be
sealed to the wall to not allow vapor or water behind it.
(plumbing must be done from backside of
nshed space)
For new framing: Mount and install rough-in tting to be
ush with nished wall.
Connect a 1/2" NPT brass pipe or copper tubing to
the steam outlet union (not included) on the generator
running the pipe to the steam head location in the wall
to connect with the steamhead rough-in tting. It is very
important that the pipe is rmly secured to the wall, so
that when the steamhead is installed it doesn’t push the
rough-in tting back into the wall. Install a 1/2” dropear
elbow on the end of the 1/2” pipe or tubing for the
rough-in tting.
Use the installation tool to tighten the housing in place
with a 1" socket and driver. Then insert the protective cap
into the housing.
For all the connections, use solder for copper joints and
Teon tape for pipe ttings and do not over tighten ttings.
DO NOT USE PVC CEMENT.