Contact the nearest Noritz agent.Abnormal combustion
Contact Noritz America if:
Any other error code appears.
An error code is indicated again after the above actions were followed.
There are any other questions.
Clean the air supply vent.(
p.21)
If the display continues, contact the nearest Noritz
agent.
[When supplying combustion
air from the indoors]
The air supply vent may be
clogged.
Have a professional check the gas supply pressure.
Contact the nearest Noritz agent.
Abnormal combustion,
low gas supply pressure
Troubleshooting-3
åÃè·ï\é¶Ç
Ç®í≤Ç◊Ç≠ÇæÇ≥Ç¢ åÃè·ï\é¶Ç
Ç®í≤Ç◊Ç≠ÇæÇ≥Ç¢
Check for an Error Code on the Remote Controller
If there is a problem with the unit, a numerical error code will ash on the remote controller.
If this occurs, take appropriate measures as listed below.
When an error code appears, the display and the operation light will
ash together.
Error Code Cause Action
Ignition error
Check whether the gas valve is open. Press the power
button to turn the unit off, open a hot water xture,
and turn the unit back on. If the ashing number
doesn't return the problem is solved.
Flashing
Remote Controller
Check to see if the condensate drain pipe is clogged
or frozen (
p.8)
Contact the installer or Noritz America Technical
Support for assistance.
Clogging of condensate
trap or drain pipe
The unit may shut off and lock before long.
Needs to be ushed the Heat Exchanger to remove
the Scale Build-up.
If the unit will shut off and locked for this error, the unit
can temporarily operate by disconnecting electrical
power until the Heat Exchanger can be ushed.
Contact Noritz America for more information about
ushing the Heat Exchanger. (866-766-7489)
The unit detects Scale Build-up
in the Heat Exchanger.
(Warning indication, and
then the unit will shut off
before long.)
The unit is locked because of repeated Scale Build-
up error codes. Must ush the Heat Exchanger to
remove the Scale Build-up.
Before ushing the Heat Exchanger, contact Noritz
America for more information.(866-766-7489)
The unit detects the Scale
Build-up in the Heat
Exchanger many times
(The unit is locked.)
#
=0-9
=1-4, F
# =0-9