Installation location
A dry, well ventilated room is suitable as an installation location. The installation location should not be
exposed to direct sunlight and not placed near a heat source, e.g. a cooker, radiator, etc.
If installation next to a heat source is unavoidable, use a suitable insulating plate or observe the following
minimum distance from the heat source:
To electric or gas oven/range 1¼” (3 cm).
To an oil or coal-fired cooker 11
13
/
16
(30cm).
To another Refrigerator or Wine Reserve 1” (2.54cm)
The floor of the installation location must not give way; if necessary, reinforce floor. The appliance must
be upright to function correctly.
For proper operation and appearance of the unit, the cabinet opening should be square and have
dimensions as shown in the next diagrams
TOP VIEW
FRONTAL VIEW
864-889mm
34” – 35”
611mm
24 1/16”
Counter opening
915mm
36”
25.4mm
1”
*24”
(610mm)
Counter opening
14mm
1/2”
(MINIMUM)
610mm
24”
Unit
624mm
24 9/16”
Counter
23 7/8”
607mm
Unit