Specifications Sheet

Table Of Contents
These warranties give you specific legal rights and you may have other rights that vary from state to state. Full warranty and limited warranty from date of installation. For complete warranty
details, refer to your Use & Care manual, or ask your dealer.
Specifications are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to making counter opening. Consult with a heating and ventilation
engineer for your specific ventilation requirements. For the most detailed information, refer to installation instructions accompanying product or write to Thermador indicating the model
number. Specifications are correct at time of printing. Thermador reserves the right to change product specifications or design without notice. Some models are certified for use in Canada.
Thermador is not responsible for products that are transported from the U.S. for use in Canada.
1 800 735 4328 | USA THERMADOR.COM | CANADA THERMADOR.CA | ©2018 BSH HOME APPLIANCES CORPORATION. ALL RIGHTS RESERVED.
Page 6 of 6
11 / 18
PRG364WDH
36-INCH GAS PRO HARMONY
®
RANGE WITH GRIDDLE
PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE
36-INCH RANGE DIMENSIONS AND CLEARANCE REQUIREMENTS WITH “FLUSH ISLAND TRIM”
Combustible
Materials
28" (711 mm)
27¼" (692 mm)
36" (914 mm) min .
to combustible
materials
24" (610 mm)
max. recess depth
Cantilever
22 5/8" (575 mm)
"
(1140 mm)
Total Clearance
Installation Clearances with Flush Island Trim
24¾" (629 mm)
If an inner wall
is used under
the cantilever counter
top, there should be a
1
/8
" (3 mm) gap from
the rear of the range
to the inner wall.
6" (152 mm) min. to
For Flush IslandFor Flush Island
Trim installations,
Trim installations,
counter surface should
counter surface should
have a cantilever edge
have a cantilever edge
meeting the back
meeting the back
section of the Flush
section of the Flush
Island Trim accessory.
Island Trim accessory.
Shaded area behind
range indicates
minimum clearance
to combustible surfaces,
combustible materials
cannot be located within
this area.
Shaded area behind
range indicates
minimum clearance
to combustible surfaces,
combustible materials
cannot be located within
this area.
35
7
/8
" (911 mm) Min.
36 ¾" (933 mm)
Max.
44
7
/8
24
5
/8
" (625 mm)
As defined in the “National Fuel Gas Code” (ANSI Z223.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1
scope and are not certified by CSA. Clearances of less than 12" (305 mm)
must be approved by the local codes and/or by the local authority having jurisdiction.
combustible surface
with Flush Island Trim