Installation instructions
Table Of Contents
Page. 19
Gas unit electrical connection
Electrical supply circuit requirements
The cord supplied with the
gas ranges having an electric
griddle or grill requires a
NEMA 5-20 receptacle. All
other gas units require a
NEMA 5-15 receptacle.
• Before you plug in an electrical cord, be sure all
controls are in the OFF position.
• A neutral supply wire must be provided from the
power source (breaker) because critical range
components, including the surface burner spark
reignition modules, require it to operate safely and
properly.
• All 120 volt models must be plugged into a mating 3-
prong, grounding-type receptacle. The receptacle
must be connected to a properly dedicated grounded
and polarized electrical power supply rated at
120VAC, Single Phase, 60Hz.
• Observe all governing codes and ordinances when
grounding. In the absence of these codes or
ordinances observe National Electrical Code ANSI/
NFPA No. 70 current issue, or the relevant Canadian
Electric Code, CSA C22.1-02.
Electrical requirements and
connection for DUAL FUEL
models
9 WARNING
An improper 240/208 VAC power supply will cause
malfunction, damage to this appliance, and possibly
create a condition of shock hazard.
9 WARNING
This product must be properly grounded.
Required dedicated circuit
• Before installing, turn power OFF at the service panel.
Lock service panel to prevent power from being
turned ON accidentally.
• Prior to servicing appliance, always disconnect
appliance electrical supply cord, if so equipped, from
wall receptacle. If appliance is hard-wired to power
supply, disconnect power to unit by turning off the
proper circuit breaker. Lock service panel to prevent
power from being turned ON accidentally.
• A neutral supply wire must be provided from the
power source (breaker) because critical range
components, including the surface burner spark re-
Model Voltage Dedicated circuit Phase
Pxx305Wx 120 VAC 15 Amps Single
Pxx366Wx 120 VAC 15 Amps Single
Pxx364WDx 120 VAC 20 Amps Single
Pxx364WLx 120 VAC 20 Amps Single
Pxx486WDx 120 VAC 20 Amps Single
Pxx486WLx 120 VAC 20 Amps Single
• Power cord and receptacle
should protrude no more than
2'' (51 mm) from the rear wall.
NOTE: Plug styles may vary.
NEMA 5-15 NEMA 5-20
G
G
N
N
2"
(51)
Double oven ranges
Models Voltage US Canada Frequency Phase
All 240/208 50 AMP 50 AMP 60 Hz. Single
Single oven ranges
Models Voltage US Canada Freq. Phase
All except
PRD364WIGx
240/208 30 AMP 40 AMP 60 Hz. Single
PRD364WIGx 240/208 40 AMP 40 AMP 60 Hz. Single
When using a receptacle it may
be necessary to recess the
receptacle's housing into the rear
wall. Refer to Local Electrical
Code to determine the minimum
volume for all electrical / junction
boxes. Follow all local electrical
codes and ordinances, and/or the
National Electric Code, as
applicable.
2" (51) max.