Installation Instruction
Table Of Contents
- Table of
- Safety
- Safety
- READ AND SAVE THESE INSTRUCTIONS
- Before you begin
- General information
- Installation considerations
- Electrical requirements
- Ductwork preparation
- Choosing the correct blower
- Attaching the hood transition
- Wall mount installation
- Discharge direction
- Cabinet installation
- Blower motor installation
- Electrical wire connection
- EXTNCB25W 25 ft. remote and in-line blower extension cable (optional)
- Built-in remote control accessory (optional)
- Make-up air damper relay switch (optional)
- Duct cover installation (optional)
- Installing grease trays, filters and spacers
- Heat lamp installation
- Installer checklist
- Before calling service
- Product data rating label
- Avant de commencer
- Renseignements généraux
- Facteurs à prendre en compte pour l'installation
- Exigences électriques
- Préparation du conduit d’aération
- Configurations de conduits courants
- Choix d'un ventilateur adéquat
- Assemblage du raccord
- Installation murale
- Installation sous une armoire
- Installation du ventilateur
- Branchement des câbles
- Câble de connexion du ventilateur EXTNCB25W (optionnel)
- Commutateur à relais pour clapet d'appoint d'air (facultatif)
- Installation de la commande à distance (optionnel)
- Assemblage du recouvrement de conduit (optionnel)
- Commutateur à relais pour clapet d'appoint d'air (facultatif)
- Installation des filtres, des plateaux à graisse et des pièces d’espacement
- Remplacement des lampes infrarouges
- Liste de vérification à l’intention de l’installateur
- Avant d’appeler le service à la clientèle
- Plaque signalétique du produit
- Antes de comenzar
- Información general
- Factores a tener en cuenta para la instalación
- Exigencias eléctricas
- Preparación del conducto de aireación
- Configuraciones de conductos comunes
- Elección de un ventilador adecuado
- Junta de la campana
- Instalación mural
- Preparación de la pared trasera
- Instalación bajo un armario
- Instalación del motor del ventilador
- Conexión de los cables
- Cable de conexión del ventilador EXTNCB25W (opcional)
- Interruptor de relé de regulador de tiro de aire de compensación (opcional)
- Instalación del mando a distancia (opcional)
- Instalación de la cubierta para el conducto (opcional)
- Instalar filtros, bandejas para la grasa y separadores
- Reemplazo de las lámparas infrarrojas
- Lista de chequeo para el instalador
- Antes de solicitar servicio
- Placa de señalización del producto
- Blank Page
- Blank Page
- Blank Page
- Blank Page
7
Electrical requirements
9 WARNING
The appliance must be grounded.
• The unit requires a 120V AC, 60Hz. 15A branch circuit.
The VTN2FZ blower in conjunction with a PHxxGWS
requires a 20 amp circuit breaker.
• The hood should only be connected to a dedicated
circuit (with ground) that has been installed according
to relevant regulations.
• When connected to a GFCI-protected supply,
Thermador Professional
®
hoods are suitable for use in
damp locations that are protected from outside
weather conditions and not subject to saturation with
water and other liquids, but can be subject to
moderate degrees of moisture (such as an outdoor
covered patio or lanai area). Refer to local codes,
NEC/CEC, and or the Authority Having Jurisdiction
(AHJ) for additional information.
• Check your local building codes for proper method of
installation. This unit should be installed in accordance
with applicable local codes or, in the absence of local
codes, with the National Electrical Code, NFPA 70 or
the Canadian Electric Code, CSA C22.1-02.
• The 25 ft. remote and in-line blower extension cable
accessory (EXTNCB25W) will only work for distances
up to 25 ft. The accessory cable must be purchased
separately. DO NOT use more than one blower
extension cable per installation.
Electrical data
• Data, including the model and serial number, is
located on the product data rating label inside the
appliance, visible after removal of the filter frame (see
“Product data rating label” on page 19”).
Ductwork preparation
• The exhaust air is discharged upwards through a duct
or directly through the outside wall into the open.
• The hood can be mounted on the wall only with a
vertical discharge.
• Proper performance is dependent upon proper
ducting. Local building codes may require the use of
make-up air systems when using ducted ventilation
systems greater than specified cubic feet per minute
(CFM) of air movement.
• The specified CFM varies from locale to locale. It is the
responsibility of the owner and the installer to
determine if additional requirements and/or standards
apply to specific installations.
• DO NOT USE FLEXIBLE DUCT; it creates back
pressure/air turbulence and reduces performance.
• Always install a metal vent cover where the ductwork
exits the house.
• Always install a metal vent cover where the ductwork
exits the house.
• Hood must be vented to the outside of building only.
• COLD WEATHER installations should have an
additional backdraft damper installed to minimize
backward cold air flow and a nonmetallic thermal
break to minimize conduction of outside temperatures
as part of the ductwork. The damper should be on the
cold air side of the thermal break. The break should
be as close as possible to where the ducting enters
the heated portion of the house.
• MAKE-UP AIR: Local building codes may require the
use of make-up air systems when using ducted
ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to
locale. It is the responsibility of the owner and the
installer to determine if additional requirements and/
or standards apply to specific installations.
• To reduce risk of fire and to properly exhaust air, be
sure to duct air outside. Do not vent exhaust air in
spaces with walls or ceilings or into attics, crawl
spaces or garages.
• Thermador
®
recommends not exceeding 50 ft
(15.24 m) equivalent of duct.
• Keep duct runs as short and straight as possible.
Elbows and transitions fittings reduce air flow
efficiency. Back to back elbows and “S” turns give very
poor delivery and are not recommended.
• A short, straight length of duct at the inlet of a remote
blower gives the best delivery.
• Hoods are supplied with a 10" (254 mm) transition. A
locally supplied transition is required for other sizes.
• Use the “Equivalent duct lengths for commonly used
transitions” table to compute permissible lengths for
duct runs to outdoors.