8. Technical data
Operating voltage: 230 V AC, +10 % –15 %
Frequency: 50 Hz
Standby: 0,3 W
Detection angle: 220°, 300°
Detection area: crosswise: max. 16 m,
frontal: max. 5 m
Installation height: 2 – 4 m
Exit-On function: yes
Brightness setting range: 5–1000/∞ lux
Switch-off delay: 1 s – 20 min
Permissible ambient temperature: –25 °C to +45 °C
Protection class: II
Protection rating: IP 55 (wall mounting) and IP 54
(ceiling installation) (category II) in
accordance with EN 60529
Switching capacity: 10 A (cos ϕ = 1)
10 AX (cos ϕ = 0.3)
Min. switching capacity: 24 V/100 mA
Switching contact: μ-Contact 230 V AC
LED lamps <2 W 60 W
LED lamps >2 W <8 W 180 W