Installation Sheet

INSTALLATION INSTRUCTIONS
For Model 72172/72173/72178-189
READ AND SAVE THESE INSTRUCTIONS
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
MOUNTING THE FIXTURE (Fig.1)
1. Shut off power at the circuit breaker and remove the old
fixture, including the mounting hardware.
2. Carefully unpack your new fixture and lay out all the parts on
a clear area. Take care not to lose any parts necessary for
installation.
3. Attach the mounting plate(M) (Part#A-020) to the outlet
box(not provided) with the two screws(C) (Size:8-32*1/2”).
4. Align the curved end of scroll arm (R) through the decorative
ring (T), secure the other end to the backplate (U) with screw
(Q) (Size:M4*10) and hex nut and gasket washer (P).
CONNECTING ELECTRICAL (Fig.2)
5. Connect the electrical wires as shown in (Fig.2), making
sure that all wire connectors are secured. If your outlet has a
ground wire (green or bare copper), connect the fixture
ground wire to it. Otherwise, connect the fixture ground wire
directly to the mounting plate using the green screw
provided.
6. Align the fixture to the mounting screw(S) (Size:8-32*1/2”)
on the mounting plate (M) and secure with knurled knobs (B)
and washers(K)(Fig1).
7. To prevent moisture from entering the outlet box and
causing a short, use clear caulking (i.e. Indoor/Outdoor
Silicone Sealant) to outline the outside off fixture back-plate
where it meets the wall leaving a space at bottom to allow
moisture a means to escape (Fig3).
COMPLETING THE INSTALLATION
8. Place candle sleeves (V) over the sockets (W).
9. Install the 3*60W (part#:72172) & 4*60W (part#:72173&
72178) light bulbs (D) in accordance with the fixtures
specification
. (DO NOT EXCEED THE MAXIMUM
WATTAGE RATING!)
(NE PAS DEPASSER LA
PUISSANCE NOMINALE MAXIMALE!)
10. Separate lamp body (O) from top cover (H) by unscrewing
the mounting screws (G) ( Size: M4*16). Align the glass (E)
into body (O) and secure with glass clips (F).
11. Re-attach body (O) to the top cover (H) with mounting
screws (G).
Your installation is now complete. Return power to the junction
box and test the fixture.
Fig.3
Fig.1
“CAUTION-RISK OF FIRE CONSULT A QUALIFIED
ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT
CONDUCTOR”
ATTENTION – RISQUE D’INCENDIE, CONSULTER UN
ÉLECTRICIEN QUALIFIÉ POUR VOUS ASSURER QUE LES
CONDUCTEURS DE LA DÉRIVATION SONT ADÉQUATS.
Set A#: A-020-1
-Mounting plate
-Ground screw
-Mounting screws (2)

Summary of content (1 pages)