Datasheet

ABSOLUTE MAXIMUM RATINGS
(1)
PIN CONFIGURATIONS
1
2
3
4
5
10
9
8
7
6
GND
V
OUT
-V
CC
-V
IN
-R
G
FB
+V
CC
V
G
+V
IN
+R
G
1
2
3
4
5
6
7
14
13
12
11
10
9
8
+V
CC
NC
FB
GND
V
OUT
V
REF
-V
CC
+V
CC
V
G
+V
IN
+R
G
-R
G
-V
IN
-V
CC
VCA822
SBOS343C SEPTEMBER 2007 REVISED DECEMBER 2008 .....................................................................................................................................
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION
(1)
SPECIFIED
PACKAGE TEMPERATURE PACKAGE ORDERING TRANSPORT
PRODUCT PACKAGE-LEAD DESIGNATOR RANGE MARKING NUMBER MEDIA, QUANTITY
VCA822ID Rail, 50
VCA822 SO-14 D 40 ° C to +85 ° C VCA822ID
VCA822IDR Tape and Reel, 2500
VCA822IDGST Tape and Reel, 250
VCA822 MSOP-10 DGS 40 ° C to +85 ° C BOS
VCA822IDGSR Tape and Reel, 2500
(1) For the most current package and ordering information see the Package Option Addendum at the end of this document, or see the TI
web site at www.ti.com .
Over operating free-air temperature range, unless otherwise noted.
VCA822 UNIT
Power supply ± 6.5 V
Internal power dissipation See Thermal Characteristics
Input voltage range ± V
S
V
Storage temperature range 65 to +125 ° C
Lead temperature (soldering, 10s) +260 ° C
Junction temperature (T
J
) +150 ° C
Junction temperature (T
J
), maximum continuous operation +140 ° C
Human body model (HBM) 2000 V
ESD ratings Charged device model (CDM) 500 V
Machine model (MM) 200 V
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated is not implied. Exposure to
absolute-maximum rated conditions for extended periods may affect device reliability.
SO-14
MSOP-10
(Top View)
(Top View)
NC = No Connection
2 Submit Documentation Feedback Copyright © 2007 2008, Texas Instruments Incorporated
Product Folder Link(s): VCA822