Datasheet

TS5A3153
SCDS215A OCTOBER 2005 REVISED JULY 2008 .....................................................................................................................................................
www.ti.com
PIN DESCRIPTION
PIN NO. NAME DESCRIPTION
1 COM Common
2 EN Enable control input
3 GND Digital ground
4 GND Digital ground
5 IN Digital control to connect the COM to NO or NC
6 NO Normally open
7 NC Normally closed
8 V
+
Power supply
PARAMETER DESCRIPTION
SYMBOL DESCRIPTION
V
COM
Voltage at COM
V
NC
Voltage at NC
V
NO
Voltage at NO
r
on
Resistance between COM and NC or COM and NO ports when the channel is ON
r
peak
Peak on-state resistance over a specified voltage range
Δ r
on
Difference of r
on
between channels in a specific device
r
on(flat)
Difference between the maximum and minimum value of r
on
in a channel over the specified range of conditions
Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the OFF state under
I
NC(OFF)
worst-case input and output conditions
I
NC(PWROFF)
Leakage current measured at the NC port during the power-off condition, V
+
= 0
Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the OFF state under
I
NO(OFF)
worst-case input and output conditions
I
NO(PWROFF)
Leakage current measured at the NO port during the power-off condition, V
+
= 0
Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the ON state and the output
I
NC(ON)
(COM) open
Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the ON state and the output
I
NO(ON)
(COM) open
Leakage current measured at the COM port, with the corresponding channel (COM to NO or COM to NC) in the ON state
I
COM(ON)
and the output (NC or NO) open
Leakage current measured at the COM port, with the corresponding channel (COM to NO or COM to NC) in the OFF
I
COM(OFF)
state and the output (NC or NO) open
I
COM(PWROFF)
Leakage current measured at the COM port during the power-off condition, V
+
= 0
V
IH
Minimum input voltage for logic high for the control input (IN, EN)
V
IL
Maximum input voltage for logic low for the control input (IN, EN)
V
I
Voltage at the control input (IN, EN)
I
IH
, I
IL
Leakage current measured at the control input (IN, EN)
Turn-on time for the switch. This parameter is measured under the specified range of conditions and by the propagation
t
ON
delay between the digital control (IN) signal and analog output (COM, NC, or NO) signal when the switch is turning ON.
Turn-off time for the switch. This parameter is measured under the specified range of conditions and by the propagation
t
OFF
delay between the digital control (IN) signal and analog output (COM, NC, or NO) signal when the switch is turning OFF.
Break-before-make time. This parameter is measured under the specified range of conditions and by the propagation
t
BBM
delay between the output of two adjacent analog channels (NC and NO) when the control signal changes state.
Charge injection is a measurement of unwanted signal coupling from the control (IN) input to the analog (NC, NO, or
COM) output. This is measured in coulomb (C) and measured by the total charge induced due to switching of the control
Q
C
input. Charge injection, Q
C
= C
L
× Δ V
COM
, C
L
is the load capacitance, and Δ V
COM
is the change in analog output
voltage.
C
NC(OFF)
Capacitance at the NC port when the corresponding channel (NC to COM) is OFF
C
NO(OFF)
Capacitance at the NO port when the corresponding channel (NO to COM) is OFF
C
NC(ON)
Capacitance at the NC port when the corresponding channel (NC to COM) is ON
C
NO(ON)
Capacitance at the NO port when the corresponding channel (NO to COM) is ON
14 Submit Documentation Feedback Copyright © 2005 2008, Texas Instruments Incorporated