Datasheet

TS5A2066
www.ti.com
SCDS184D JANUARY 2005REVISED APRIL 2010
Electrical Characteristics for 3.3-V Supply
(1)
V
+
= 3 V to 3.6 V, T
A
= –40°C to 85°C (unless otherwise noted)
PARAMETER SYMBOL TEST CONDITIONS T
A
V
+
MIN TYP MAX UNIT
Analog Switch
Analog signal
V
COM
, V
NO
0 V
+
V
range
0 V
NO
V
+
, 25°C 10 12 15
ON-state Switch ON,
r
on
3 V
I
COM
= –24 mA,
resistance See Figure 13
Full 12 20
ON-state 25°C 0.04 0.5 1.5
resistance match V
NO
= 2.1 V, Switch ON,
Δr
on
3 V
between I
COM
= –24 mA, See Figure 13
Full 0.01 3.5
channels
ON-state 25°C 6 7 8
0 V
NO
V
+
, Switch ON,
resistance r
on(flat)
3 V
I
COM
= –24 mA, See Figure 13
Full 9 12
flatness
V
NO
= 1 V, 25°C –30 –6 30
NO V
COM
= 3 V,
Switch OFF,
OFF leakage I
NO(OFF)
or 3.6 V nA
See Figure 14
Full –40 40
current V
NO
= 3 V,
V
COM
= 1 V,
V
COM
= 1 V, 25°C –50 –7 50
COM V
NO
= 3 V,
Switch OFF,
OFF leakage I
COM(OFF)
or 3.6 V nA
See Figure 14
Full –50 50
current V
COM
= 3 V,
V
NO
= 1 V,
V
NO
= 1 V, 25°C –40 –7 40
NO V
COM
= Open,
Switch ON,
ON leakage I
NO(ON)
or 3.6 V nA
See Figure 15
Full –40 40
current V
NO
= 3 V,
V
COM
= Open,
V
COM
= 1 V, 25°C –70 –20 70
COM V
NO
= Open,
Switch ON,
ON leakage I
COM(ON)
or 3.6 V nA
See Figure 15
Full –70 70
current V
COM
= 3 V,
V
NO
= Open,
Digital Control Input (IN)
Input logic high V
IH
Full V
+
× 0.7 5.5 V
Input logic low V
IL
Full 0 V
+
× 0.3 V
25°C –0.1 0.05 0.1
Input leakage
I
IH
, I
IL
V
I
= 5.5 V or 0 3.6 V mA
current
Full –1 1
(1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum
Copyright © 2005–2010, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Link(s): TS5A2066