Datasheet

Absolute Maximum Ratings
(1)
Recommended Operating Conditions
TS321
www.ti.com
...................................................................................................................................... SLOS489B DECEMBER 2005 REVISED SEPTEMBER 2008
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
Single 32
V
CC
Supply voltage
(2)
V
Dual ± 16
V
ID
Differential input voltage
(3)
32 V
V
I
Input voltage range
(2) (4)
0.3 32 V
I
I
Input current
(4)
50 mA
t
short
Duration of output short circuit to ground Unlimited
D package 97
θ
JA
Package thermal impedance, junction to free air
(5) (6)
° C/W
DBV package 206
T
J
Operating virtual junction temperature 150 ° C
T
stg
Storage temperature range 65 150 ° C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) These voltage values are with respect to the midpoint between V
CC+
and V
CC
.
(3) Differential voltages are at IN+ with respect to IN .
(4) Neither input must ever be more positive than V
CC+
or more negative than V
CC
.
(5) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) T
A
)/ θ
JA
. Selecting the maximum of 150 ° C can affect reliability.
(6) The package thermal impedance is calculated in accordance with JESD 51-7.
MIN MAX UNIT
Single supply 3 30
V
CC
Supply voltage V
Dual supply ± 1.5 ± 15
T
A
Operating free-air temperature 40 125 ° C
Copyright © 2005 2008, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): TS321