Datasheet

TPS7A45xx
www.ti.com
SLVS720D JUNE 2008REVISED AUGUST 2011
ELECTRICAL CHARACTERISTICS
(1)
Over operating temperature range T
J
= 40°C to 125°C (unless otherwise noted)
PARAMETER TEST CONDITIONS T
J
MIN TYP
(2)
MAX UNIT
I
LOAD
= 0.5 A 25°C 1.9
Minimum input voltage
(3)
V
IN
V
(4)
I
LOAD
= 1.5 A Full range 2.1 2.5
V
IN
= 2.21 V, I
LOAD
= 1 mA 25°C 1.485 1.5 1.515
TPS7A4515
V
IN
= 2.5 V to 20 V,
Full range 1.447 1.5 1.545
I
LOAD
= 1 mA to 1.5 A
V
IN
= 2.3 V, I
LOAD
= 1 mA 25°C 1.782 1.8 1.818
TPS7A4518
V
IN
= 2.8 V to 20 V,
Full range 1.737 1.8 1.854
I
LOAD
= 1 mA to 1.5 A
V
OUT
Regulated output voltage
(5)
V
V
IN
= 3 V, I
LOAD
= 1 mA 25°C 2.475 2.5 2.525
TPS7A4525
V
IN
= 3.5 V to 20 V,
Full range 2.412 2.5 2.575
I
LOAD
= 1 mA to 1.5 A
V
IN
= 3.8 V, I
LOAD
= 1 mA 25°C 3.266 3.3 3.333
TPS7A4533
V
IN
= 4.3 V to 20 V,
Full range 3.2 3.3 3.4
I
LOAD
= 1 mA to 1.5 A
V
IN
= 2.21 V, I
LOAD
= 1 mA 25°C 1.197 1.21 1.222
V
ADJ
ADJ pin voltage
(3) (5)
TPS7A4501 V
V
IN
= 2.5 V to 20 V,
Full range 1.174 1.21 1.246
I
LOAD
= 1 mA to 1.5 A
ΔV
IN
= 2.21 V to 20 V,
TPS7A4515 Full range 2 6
I
LOAD
= 1 mA
ΔV
IN
= 2.3 V to 20 V,
TPS7A4518 Full range 2.5 7
I
LOAD
= 1 mA
ΔV
IN
= 3 V to 20 V,
Line regulation TPS7A4525 Full range 3 10 mV
I
LOAD
= 1 mA
ΔV
IN
= 3.8 V to 20 V,
TPS7A4533 Full range 3.5 10
I
LOAD
= 1 mA
ΔV
IN
= 2.21 V to 20 V,
TPS7A4501
(3)
Full range 1.5 3
I
LOAD
= 1 mA
25°C 2 9
V
IN
= 2.5 V,
TPS7A4515
ΔI
LOAD
= 1 mA to 1.5 A
Full range 18
25°C 2 10
V
IN
= 2.8 V,
TPS7A4518
ΔI
LOAD
= 1 mA to 1.5 A
Full range 20
25°C 2.5 15
V
IN
= 3.5 V,
TPS7A4525
ΔI
LOAD
= 1 mA to 1.5 A
Full range 30
25°C 3 20
Load regulation mV
V
IN
= 4.3 V, -40°C to
TPS7A4533 30
ΔI
LOAD
= 1 mA to 1.5 A +85°C
Full range 70
25°C 2 8
V
IN
= 2.5 V, -40°C to
TPS7A4501
(3)
8
ΔI
LOAD
= 1 mA to 1.5 A +85°C
Full range 18
(1) The TPS7A45xx regulators are tested and specified under pulse load conditions such that T
J
T
A
. They are fully tested at T
A
= 25°C.
Performance at 40°C and 125°C is specified by design, characterization, and correlation with statistical process controls.
(2) Typical values represent the likely parametric nominal values determined at the time of characterization. Typical values depend on the
application and configuration and may vary over time. Typical values are not ensured on production material.
(3) The TPS7A4501 is tested and specified for these conditions with the ADJ pin connected to the OUT pin.
(4) For the TPS7A4501, TPS7A4515 and TPS7A4518, dropout voltages are limited by the minimum input voltage specification under some
output voltage/load conditions.
(5) Operating conditions are limited by maximum junction temperature. The regulated output voltage specification does not apply for all
possible combinations of input voltage and output current. When operating at maximum input voltage, the output current range must be
limited. When operating at maximum output current, the input voltage range must be limited.
Copyright © 20082011, Texas Instruments Incorporated 3