Datasheet

TPS65950
SWCS032EOCTOBER 2008REVISED JANUARY 2011
www.ti.com
Table 8-1. Main Charge Electrical Characteristics
VBAT = 3.6 V, R
S
= 0.22 , unless otherwise specified (continued)
Parameter Test Conditions Min Typ Max Unit
ADCIN1 dc current source for ADCIN1 = 1 V, ITHSENS[2:0] = 000 (maximum MADC 9.5 10 10.5 μA
temperature measurement input voltage = 0.875 V), after TRIM done by
ISRCTRIM[3:0]
ITHSENS[2:0] = 001 14 20 26
ITHSENS[2:0] = 010 21 30 39
ITHSENS[2:0] = 011 28 40 52
ITHSENS[2:0] = 100 35 50 65
ITHSENS[2:0] = 101 42 60 78
ITHSENS[2:0] = 110 49 70 91
ITHSENS[2:0] = 111 56 80 104
Constant current loop After trimming (±1.10%), VAC = 5.4 V or VBUS = 5.0 V, –11% 11%
accuracy VBAT = 3.6 V, CHGIREG = (value relative to I
CHG
= 0.6
A), VCCS–VBATS rising voltage, monitoring ICTLAC1 or
ICTLUSB1, CGAIN = 1, overtemperature (ambient 0°C
to 50°C) (including the bandgap accuracy
overtemperature ±0.5% and the R
sense
resistor accuracy
±1%)
After trimming 0.55%), VAC = 5.4 V or VBUS = 5.0 V, –3.15% 3.15%
VBAT = 3.6 V, CHGIREG = (value relative to I
CHG
= 0.6
A), VCCS–VBATS rising voltage, monitoring ICTLAC1 or
ICTLUSB1, CGAIN = 0, overtemperature (ambient 0°C
to 50°C) (including the bandgap accuracy
overtemperature ±0.5% and the R
sense
resistor accuracy
±1%)
Constant current loop offset At error amplifier input, before loop trim. Including DAC –46.8 46.8 mV
offset, I-to-V offset after I-to-V trim, error amplifier offset
Constant voltage loop After trimming 0.14%), VAC = 5.4 V or VBUS = 5.0 V, –0.28% 0.28%
accuracy at room temperature, CHGVREG = (value relative to
VBAT = 4.37 V), VBAT rising voltage, monitoring
ICTLAC1 or ICTLUSB1
After trimming 0.14%), VAC = 5.4 V or VBUS = 5.0 V –0.82% 0.82%
overtemperature (ambient 0°C to 50°C), CHGVREG =
(value relative to VBAT = 4.37 V), VBAT rising voltage,
monitoring ICTLAC1 or ICTLUSB1 (including the
bandgap accuracy overtemperature ±0.5%)
Charger presence detect VBAT = 3.6 V, rising edge VBAT+0.3 VBAT+0.4 VBAT+0.6 V
threshold
VBAT = 3.6 V, falling edge VBAT VBAT+0.1 VBAT+0.3
Battery threshold when default VAC = 5.4 V or VBUS = 5.0 V, VBATOVEN = 1, 4.45 4.55 4.65 V
value
(3)
VBATOVTH(3:0) = default, MESBAT = 1, VBAT rising
voltage, monitoring VBATOV status signal
ac charger overvoltage VBAT = 3.6 V, VACCHGOVEN = 1, VACCHGOVTH(3:0) 6.24 6.5 7 V
threshold when default = default, VAC rising voltage, monitoring VACCHGOV
value
(3)
status signal
VBUS overvoltage threshold VBAT = 3.6 V, VBUSOVEN = 1, VBUSOVTH(3:0) = 5.28 5.5 5.9 V
when default value
(3)
default, VBUS rising voltage, monitoring VBUSOV status
signal
Main charge main battery Measured through ADCIN1 rising voltage and sourced 67.5 75 82.5 k
presence impedance current, monitoring BATSTS value
detection threshold
Main charge main battery Force ADCIN1 voltage, monitor BATSTS value 750 mV
presence voltage detection
threshold
Temperature detection For low temperature (2°C/3°C) –3 3 °C
accuracy For high temperature (43°C/50°C) –5 5
Battery voltage accuracy Tested for VBAT = 2.9, 3.6, and 4.2 V VBAT–0.1 VBAT VBAT+0.1 V
Current charge accuracy Tested for ICHG = 600 mA ICHG–0.04 ICHG ICHG+0.04 A
(3) Can be changed by programming the associated threshold register
120 Battery Interface Copyright © 2008–2011, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): TPS65950