Datasheet



SLVS401 − AUGUST 2001
5
www.ti.com
electrical characteristics over recommended operating junction-temperature range,
2.9 V V
I(VIN)
5.5 V, V
I(ENx)
= 0 V, T
J
= −40°C to 100°C (unless otherwise noted)
enable input, ENx (active low)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
I
I
Input current, pullup (source) V
I(ENx
)
= 0 V
5 µA
enable input, ENx (active high)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
I
I
Input current, pulldown (sink) V
I(ENx)
= 5 V 5 µA
logic output, OC
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Current sinking at V
O
= 0.4 V 1 mA
thermal shutdown characteristics
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
First thermal shutdown (shuts down switch or regulator
in overcurrent)
Occurs at or above specified temperature
when overcurrent is present.
120
Recovery from thermal shutdown 110
°C
Second thermal shutdown (shuts down all switches and
regulator)
Occurs on rising temperature, irrespective of
overcurrent.
155
°C
Second thermal shutdown hysteresis 10