Datasheet


  
SLIS110A − APRIL 2003 − REVISED MAY 2005
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Regulated input voltage (see Notes 1 and 2), V
DD
−0.3 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage (see Notes 1 and 2), V
O
−0.3 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage (see Notes 1 and 2), V
IN
−0.3 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DC input current on terminals CH1P, CH1N, CH2P, and CH2N (see Notes 1 and 2), I
IN
2 mA. . . . . . . . . . . .
DC input voltage on terminals CH1P, CH1N, CH2P and CH2N (see Notes 1 and 2), V
DCIN
14 V. . . . . . . . . .
Thermal impedance junction to ambient, θ
JA
120°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous power dissipation, P
D
200 mW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrostatic discharge susceptibility (see Note 3), V
(HBMESD)
2 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating ambient temperature range, T
A
−40°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature (soldering, 10 sec), T
LEAD
265°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to GND.
2. Absolute negative voltage on these terminals is not to go below –0.5 V.
3. The human body model is a 100-pF capacitor discharged through a 1.5-k resistor into each terminal.
recommended operating conditions
MIN MAX UNITS
Regulated input voltage, V
DD
−0.3 5.5 V
Output voltage, V
O
−0.3 5.5 V
Input voltage, V
IN
0.05 V
DD
− 0.05 V
DC input current on terminals CH1P, CH1N, CH2P, and CH2N, I
IN
−1 1 µA
DC input voltage on terminals CH1P, CH1N, CH2P, and CH2N, V
DCIN
Vref, (V
DD
/2) V
Continuous power dissipation, P
D