Datasheet

TMP411-Q1
SBOS527F DECEMBER 2010REVISED NOVEMBER 2013
www.ti.com
Table 2. Temperature Data Format
(Local and Remote Temperature High Bytes) (continued)
LOCAL/REMOTE TEMPERATURE REGISTER HIGH BYTE VALUE (1°C RESOLUTION)
TEMP (°C) STANDARD BINARY EXTENDED BINARY
BINARY HEX BINARY HEX
175 0111 1111 7F 1110 1111 EF
191 0111 1111 7F 1111 1111 FF
NOTE
Whenever changing between standard and extended temperature ranges, be aware that
the temperatures stored in the temperature limit registers are NOT automatically
reformatted to correspond to the new temperature range format. These temperature limit
values must be reprogrammed in the appropriate binary or extended binary format.
Both local and remote temperature data use two bytes for data storage. The high byte stores the temperature
with 1°C resolution. The second or low byte stores the decimal fraction value of the temperature and allows a
higher measurement resolution; see Table 3. The measurement resolution for the remote channel is 0.0625°C,
and is not adjustable. The measurement resolution for the local channel is adjustable; it can be set for 0.5°C,
0.25°C, 0.125°C, or 0.0625°C by setting the RES1 and RES0 bits of the Resolution Register; see the Resolution
Register section.
10 Submit Documentation Feedback Copyright © 2010–2013, Texas Instruments Incorporated
Product Folder Links: TMP411-Q1