Datasheet

1.90
1.88
1.86
1.84
1.82
1.80
1.78
1.76
1.74
1.72
1.70
OutputVoltage(V)
-40 -25 -10
5
20 35 50 65 80 95 110 125
Temperature( C)
°
I =200mA
I =10mA
I =150mA
OUT
OUT
OUT
0 30 60 90 120 150 180 210
Output Current (mA)
180
160
140
120
100
80
60
40
20
0
Dropout Voltage (mV)
+125 C
+85 C
+25 C
40 C-
°
°
°
°
250
200
150
100
50
0
DropoutVoltage(mV)
2.25 2.75 3.25 3.75 4.25
4.75
InputVoltage(V)
+125 C
+85 C
+25 C
40 C-
°
°
°
°
I =200mA
OUT
2.1 2.6 3.1 3.6 4.1 4.6 5.1 5.6
InputVoltage(V)
1.90
1.88
1.86
1.84
1.82
1.80
1.78
1.76
1.74
1.72
1.70
OutputVoltage(V)
+125 C
+85 C
+25 C
40 C-
°
°
°
°
I =10mA
OUT
2.1 2.6 3.1 3.6 4.1 4.6 5.1 5.6
InputVoltage(V)
1.90
1.88
1.86
1.84
1.82
1.80
1.78
1.76
1.74
1.72
1.70
OutputVoltage(V)
+125 C
+85 C
+25 C
40 C-
°
°
°
°
I =200mA
OUT
TLV700xx
SLVSA00D SEPTEMBER 2009REVISED NOVEMBER 2012
www.ti.com
TYPICAL CHARACTERISTICS
Over operating temperature range (T
J
= –40°C to +125°C), V
IN
= V
OUT(TYP)
+ 0.5 V or 2.0 V, whichever is greater; I
OUT
= 10
mA, V
EN
= V
IN
, C
OUT
= 1.0 μF, unless otherwise noted. Typical values are at T
J
= +25°C.
TLV70018 TLV70018
LINE REGULATION LINE REGULATION
Figure 2. Figure 3.
TLV70018 DROPOUT VOLTAGE
LOAD REGULATION vs INPUT VOLTAGE
Figure 4. Figure 5.
DROPOUT VOLTAGE vs OUTPUT CURRENT TLV70018
V
OUT
= 4.8V OUTPUT VOLTAGE vs TEMPERATURE
Figure 6. Figure 7.
6 Submit Documentation Feedback Copyright © 2009–2012, Texas Instruments Incorporated