Datasheet

TLV3401, TLV3402, TLV3404
FAMILY OF NANOPOWER OPEN DRAIN OUTPUT COMPARATORS
SLCS135A AUGUST 2000 REVISED NOVEMBER 2000
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
(see Note 1) 17 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Differential input voltage, V
ID
±20 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
(see Notes 1 and 2) 0 to V
CC
+ 5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input current range, I
I
±10 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current range, I
O
±10 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: C suffix 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I suffix 40°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum junction temperature, T
J
150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltages, are with respect to GND.
2. Input voltage range is limited to 20 V or V
CC
+ 5 V, whichever is smaller.
DISSIPATION RATING TABLE
PACKAGE
θ
JC
(°C/W)
θ
JA
(°C/W)
T
A
25°C
POWER RATING
T
A
= 125°C
POWER RATING
D (8) 38.3 176 710 mW 142 mW
D (14) 26.9 122.6 1022 mW 204.4 mW
DBV (5) 55 324.1 385 mW 77.1 mW
DGK (8) 54.2 259.9 481 mW 96.2 mW
N (14) 32 78 1600 mW 320.5 mW
P (8) 41 104 1200 mW 240.4 mW
PW (14) 29.3 173.6 720 mW 144 mW
recommended operating conditions
MIN MAX UNIT
Single su
pp
ly
C-suffix
2.5 16
Su
pp
ly voltage V
CC
Single
supply
I-suffix
2.7 16
V
Supply
voltage
,
V
CC
S
p
lit su
pp
ly
C-suffix
±1.25 ±8
V
Split
supply
I-suffix
±1.35 ±8
Common-mode input voltage range, V
ICR
0.1 V
CC
+5 V
O
p
erating free air tem
p
erature T
A
C-suffix 0 70
°C
Operating
free
-
air
temperature
,
T
A
I-suffix
40 125
°C