SLOS209G − JANUARY 1998 − REVISED FEBRUARY 2004
5
WWW.TI.COM
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
DD
(see Note 1) 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Differential input voltage, V
ID
(see Note 2) ±V
DD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
(any input, see Note 1) −0.3 V to V
DD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input current, I
I
(any input) ±4 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current, I
O
±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Total current into V
DD+
±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Total current out of GND ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Duration of short-circuit current (at or below) 25°C (see Note 3) unlimited. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: C suffix 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I suffix −40°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Q suffix −40°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M suffix 55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltages, are with respect to GND.
2. Differential voltages are at the noninverting input with respect to the inverting input. Excessive current flows when input is brought
below GND − 0.3 V.
3. The output may be shorted to either supply. Temperature and/or supply voltages must be limited to ensure that the maximum
dissipation rating is not exceeded.
DISSIPATION RATING TABLE
PACKAGE
T
A
25
°
C
DERATING FACTOR
T
A
= 70
°
C
T
A
= 85
°
C
T
A
= 125
°
C
PACKAGE
T
A
25 C
POWER RATING
DERATING FACTOR
ABOVE T
A
= 25°C
T
A
= 70 C
POWER RATING
T
A
= 85 C
POWER RATING
T
A
= 125 C
POWER RATING
D 725 mW 5.8 mW/°C 464 mW 377 mW 145 mW
DBV 437 mW 3.5 mW/°C 280 mW 227 mW 87 mW
DGK 424 mW 3.4 mW/°C 271 mW 220 mW 85 mW
DGS 424 mW 3.4 mW/°C 271 mW 220 mW 85 mW
FK 1375 mW 11.0 mW/°C 672 mW 546 mW 210 mW
JG 1050 mW 8.4 mW/°C 880 mW 714 mW 275 mW
N 1150 mW 9.2 mW/°C 736 mW 598 mW 230 mW
P 1000 mW 8.0 mW/°C 640 mW 520 mW 200 mW
PW 700 mW 5.6 mW/°C 448 mW 364 mW 140 mW
U 675 mW 5.4 mW/°C 432 mW 350 mW 135 mW
recommended operating conditions
C SUFFIX I SUFFIX Q SUFFIX M SUFFIX
UNIT
MIN MAX MIN MAX MIN MAX MIN MAX
UNIT
Supply voltage, V
DD
2.5 6 2.5 6 2.5 6 2.5 6 V
Input voltage range, V
I
GND V
DD+
1.3 GND V
DD+
1.3 GND V
DD+
1.3 GND V
DD+
1.3 V
Common-mode input voltage, V
IC
GND V
DD+
1.3 GND V
DD+
1.3 GND V
DD+
1.3 GND V
DD+
1.3 V
Operating free-air temperature, T
A
0 70 −40 125 −40 125 −55 125 °C