Datasheet

 
      
    
SLAS251A − DECEMBER 1999 − REVISED JANUARY 2003
7
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
control and timing (continued)
configuration
Configuration data is stored in one 12-bit configuration register (CFR) (see Table 2 for CFR bit definitions). Once
configured after first power up, the information is retained in the H/W or S/W power down state. When the device
is being configured, a write CFR cycle is issued by the host processor. This is a 16-bit write. If the SCLK stops
after the first 8 bits are entered, then the next eight bits can be taken after the SCLK is resumed. The status of
the CFR can be read with a read CFR command when the device is programmed for one-shot conversion mode
(CFR D[6,5] = 00).
Table 2. TLV1504/TLV1508 Configuration Register (CFR) Bit Definitions
BIT DEFINITION
D11 Reference select
0: External
1: Internal (Tie REFM to analog ground if the Internal reference is selected.)
D10 Internal reference voltage select
0: Internal ref = 4 V 1: internal ref = 2 V
D9 Sample period select
0: Short sampling 12 SCLKs (1x sampling time)
1: Long sampling 24 SCLKs (2x sampling time)
D(8,7) Conversion clock source select
00: Conversion clock = internal OSC
01: Conversion clock = SCLK
10: Conversion clock = SCLK/4
11: Conversion clock = SCLK/2
D(6,5) Conversion mode select
00: Single shot mode [FIFO not used, D(1,0) has no effect.]
01: Repeat mode
10: Sweep mode
11: Repeat sweep mode
D(4,3)
TLV1508 TLV1504
D(4,3)
Sweep auto sequence select
00: 0−1−2−3−4−5−6−7
01: 0−2−4−6−0−2−4−6
10: 0−0−2−2−4−4−6−6
11: 0−2−0−2−0−2−0−2
Sweep auto sequence select
00: N/A
01: 0−1−2−3−0−1−2−3
10: 0−0−1−1−2−2−3−3
11: 0−1−0−1−0−1−0−1
D2 EOC/INT − pin function select
0: Pin used as INT
1: Pin used as EOC
D(1,0) FIFO trigger level (sweep sequence length)
00: Full (INT
generated after FIFO level 7 filled)
01: 3/4 (INT
generated after FIFO level 5 filled)
10: 1/2 (INT
generated after FIFO level 3 filled)
11: 1/4 (INT
generated after FIFO level 1 filled)
These bits only take effect in conversion modes 10 and 11.
sampling
The sampling period starts after the first 4 input data are shifted in if they are decoded as one of the conversion
commands. These are select analog input (channel 0 through 7) and select test (channel 1 through 3).