Datasheet

  
  
µ  
SLOS193B − FEBRUARY 1997 − REVISED MAY 2004
27
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
TLE2062M electrical characteristics at specified free-air temperature, V
CC±
= ±5 V
PARAMETER TEST CONDITIONS
T
A
TLE2062M
TLE2062AM
TLE2062BM
UNIT
A
MIN TYP MAX
TLE2062M
25°C 1 5
TLE2062M
Full range 7
V
IO
Input offset voltage
TLE2062AM
25°C 0.9 4
mV
V
IO
Input offset voltage TLE2062AM
Full range 6
mV
TLE2062BM
25°C 0.7 3
TLE2062BM
V
IC
= 0,
R
S
= 50
Full range 5
α
VIO
Temperature coefficient of input offset voltage
V
IC
= 0, R
S
= 50
Full range
6 µV/°C
Input offset voltage long-term drift (see Note 4) 25°C 0.04 µV/mo
I
IO
Input offset current
25°C 1 pA
I
IO
Input offset current
Full range 15 nA
I
IB
Input bias current
25°C 3 pA
I
IB
Input bias current
Full range 30 nA
V
ICR
Common-mode input voltage range
25°C
1.6
to
4
−2
to
6
V
V
ICR
Common-mode input voltage range
Full range
1.6
to
4
V
R
L
= 10 k
25°C 3.5 3.7
R
L
= 10 k
Full range 3
V
OM+
Maximum positive peak output
FK and JG
packages
R
L
= 600
25°C 2.5 3.6
V
V
OM+
Maximum positive peak output
voltage swing
FK and JG
packages
R
L
= 600
Full range 2
V
voltage swing
D and P
packages
R
L
= 100
25°C 2.5 3.1
D and P
packages
R
L
= 100
Full range 2
R
L
= 10 k
25°C 3.5 3.9
R
L
= 10 k
Full range −3
V
OM
Maximum negative peak output
FK and JG
packages
R
L
= 600
25°C 2.5 3.5
V
V
OM
Maximum negative peak output
voltage swing
FK and JG
packages
R
L
= 600
Full range −2
V
voltage swing
D and P
packages
R
L
= 100
25°C 2.5 2.7
D and P
packages
R
L
= 100
Full range −2
V
O
= ±2.8 V,
R
L
= 10 k
25°C 15 80
V
O
= ±2.8 V, R
L
= 10 k
Full range
2
V
O
= 0 to 2.5 V,
R
L
= 600
25°C 1 65
FK and JG
packages
V
O
= 0 to 2.5 V, R
L
= 600
Full range
0.5
A
VD
Large-signal differential voltage
FK and JG
packages
V
O
= 0 to −2.5 V,
R
L
= 600
25°C 1 16
V/mV
A
VD
Large-signal differential voltage
amplification
V
O
= 0 to −2.5 V
,
R
L
= 600
Full range
0.5
V/mV
amplification
V
O
= 0 to 2 V,
R
L
= 100
25°C 0.75 45
D and P
packages
V
O
= 0 to 2 V, R
L
= 100
Full range
0.5
D and P
packages
V
O
= 0 to −2 V,
R
L
= 100
25°C 0.5 3
V
O
= 0 to −2 V, R
L
= 100
Full range 0.25
Full range is −55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at T
A
= 150°C extrapolated
to T
A
= 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.