Datasheet

TLE202x, TLE202xA, TLE202xB, TLE202xY
EXCALIBUR HIGH-SPEED LOW-POWER PRECISION
OPERATIONAL AMPLIFIERS
SLOS191D FEBRUARY 1997 REVISED NOVEMBER 2010
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
25
TLE2024 electrical characteristics at specified free-air temperature, V
CC
= 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
T
TLE2024M TLE2024AM TLE2024BM
UNIT
PARAMETER TEST CONDITIONS
T
A
MIN TYP MAX MIN TYP MAX MIN TYP MAX
UNIT
V
Input offset voltage
25°C 1100 850 600
V
V
IO
Input offset voltage
Full range 1300 1050 800
μV
α
VIO
Temperature coefficient of
input offset voltage
Full range 2 2 2 μV/°C
Input offset voltage long-term
drift (see Note 4)
V
IC
= 0, R
S
= 50 Ω
25°C
0.005 0.005 0.005 μV/mo
I
Input offset current
25°C 0.6 6 0.5 6 0.4 6
nA
I
IO
Input offset current
Full range 10 10 10
nA
I
Input bias current
25°C 45 70 40 70 35 70
nA
I
IB
Input bias current
Full range 90 90 90
nA
V
Common-mode input voltage
R 50 Ω
25°C
0
to
3.5
0.3
to
4
0
to
3.5
0.3
to
4
0
to
3.5
0.3
to
4
V
V
ICR
Common mode input voltage
range
R
S
= 50 Ω
Full range
0
to
3.2
0
to
3.2
0
to
3.2
V
V
Maximum positive peak
25°C 3.9 4.2 3.9 4.2 4 4.3
V
V
OM +
Maximum positive peak
output voltage swing
R 10 kΩ
Full range 3.7 3.7 3.8
V
V
Maximum negative peak
R
L
= 10 kΩ
25°C 0.7 0.8 0.7 0.8 0.7 0.8
V
V
OM
Maximum negative peak
output voltage swing
Full range 0.95 0.95 0.95
V
A
Large-signal differential
V 1 4 V to 4 V
R 10 kΩ
25°C 0.2 1.5 0.3 1.5 0.4 1.5
V/ V
A
VD
Large signal differential
voltage amplification
V
O
= 1.4 V to 4 V, R
L
= 10 kΩ
Full range
0.1 0.1 0.1
V/μV
CMRR
Common mode rejection ratio
V V min
R 50 Ω
25°C 80 90 82 92 85 95
dB
CMRR Common-mode rejection ratio V
IC
= V
ICR
min, R
S
= 50 Ω
Full range
80 82 85
dB
k
SVR
Suppl
y
-volta
g
e re
j
ection ratio
V ±2 5 V to ±15 V
25°C 98 112 100 115 103 117
dB
k
SVR
Supply voltage rejection ratio
(ΔV
CC
±
/ΔV
IO
)
V
CC
±
= ±2.5 V to ±15 V
Full range 93 95 98
dB
I
Supply current
25°C 800 1200 800 1200 800 1200
A
I
CC
Supply current
V
O
= 0
No load
Full range 1200 1200 1200
μA
ΔI
CC
Supply current change over
operating temperature range
V
O
=
0
,
N
o
l
oa
d
Full range 50 50 50 μA
Full range is 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at T
A
= 150°C extrapolated to T
A
= 25°C using the Arrhenius equation
and assuming an activation energy of 0.96 eV.