Datasheet
TLE202x, TLE202xA, TLE202xB, TLE202xY
EXCALIBUR HIGH-SPEED LOW-POWER PRECISION
OPERATIONAL AMPLIFIERS
SLOS191D − FEBRUARY 1997 − REVISED NOVEMBER 2010
22
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
•
TLE2021 electrical characteristics at specified free-air temperature, V
CC
= ±15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
T
†
TLE2021M TLE2021BM
UNIT
PARAMETER TEST CONDITIONS
T
A
†
MIN TYP MAX MIN TYP MAX
UNIT
V
Input offset voltage
25°C 120 500 40 100
V
V
IO
Input offset voltage
Full range 1000 200
μV
α
VIO
Temperature coefficient of
input offset voltage
Full range 2 2 μV/°C
Input offset voltage long-term drift (see Note 4)
V
IC
= 0, R
S
= 50 Ω
25°C
0.006 0.006 μV/mo
I
Input offset current
V
IC
= 0
,
R
S
= 50 Ω
25°C 0.2 6 0.2 6
nA
I
IO
Input offset current
Full range 10 10
nA
I
Input bias current
25°C 25 70 25 70
nA
I
IB
Input bias current
Full range 90 90
nA
V
Common-mode in
p
ut
R 50 Ω
25°C
−15
to
13.5
−15.3
to
14
−15
to
13.5
−15.3
to
14
V
V
ICR
Common mode input
voltage range
R
S
= 50 Ω
Full range
−15
to
13.2
−15
to
13.2
V
V
Maximum
p
ositive
p
eak
25°C 14 14.3 14 14.3
V
V
OM +
Maximum positive peak
output voltage swing
R 10 kΩ
Full range 13.8 13.8
V
V
Maximum ne
g
ative peak
R
L
= 10 kΩ
25°C −13.7 −14.1 −13.7 −14.1
V
V
OM −
Maximum negative peak
output voltage swing
Full range − 13.6 −13.6
V
A
Lar
g
e-si
g
nal differential
V ± 10 V
R 10 kΩ
25°C 1 6.5 1 6.5
V/ V
A
VD
Large signal differential
voltage amplification
V
O
= ±10 V, R
L
= 10 kΩ
Full range
0.5 0.5
V/μV
CMRR
Common mode rejection ratio
V V min
R 50 Ω
25°C 100 115 100 115
dB
CMRR Common-mode rejection ratio V
IC
= V
ICR
min, R
S
= 50 Ω
Full range
96 96
dB
k
Suppl
y
-volta
g
e re
j
ection ratio
V ± 2 5 V to ±15 V
25°C 105 120 105 120
dB
k
SVR
Supply voltage rejection ratio
(ΔV
CC
±
/ΔV
IO
)
V
CC
±
= ± 2.5 V to ±15 V
Full range 100 100
dB
I
Supply current
25°C 200 300 200 300
A
I
CC
Supply current
V
O
= 0
No load
Full range 300 300
μA
ΔI
CC
Supply current change over
operating temperature range
V
O
=
0
,
N
o
l
oa
d
Full range 10 10 μA
†
Full range is − 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at T
A
= 150°C extrapolated to T
A
= 25°C using the Arrhenius equation
and assuming an activation energy of 0.96 eV.