TLE2024 electrical characteristics at specified free-air temperature, V
CC
= ±15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
T
TLE2024C TLE2024AC TLE2024BC
UNIT
PARAMETER TEST CONDITIONS
T
A
MIN TYP MAX MIN TYP MAX MIN TYP MAX
UNIT
V
Input offset voltage
25°C 1000 750 500
V
V
IO
Input offset voltage
Full range 1200 950 700
μV
α
VIO
Temperature coefficient of
input offset voltage
Full range 2 2 2 μV/°C
Input offset voltage long-term
drift (see Note 4)
V
IC
= 0, R
S
= 50 Ω
25°C
0.006 0.006 0.006 μV/mo
I
Input offset current
25°C 0.6 6 0.5 6 0.4 6
nA
I
IO
Input offset current
Full range 10 10 10
nA
I
Input bias current
25°C 50 70 45 70 40 70
nA
I
IB
Input bias current
Full range 90 90 90
nA
V
Common-mode input volta
g
e
R 50 Ω
25°C
15
to
13.5
15.3
to
14
15
to
13.5
15.3
to
14
15
to
13.5
15.3
to
14
V
V
ICR
Common mode input voltage
range
R
S
= 50 Ω
Full range
15
to
13.5
15
to
13.5
15
to
13.5
V
V
Maximum positive peak output
25°C 13.8 14.1 13.9 14.2 14 14.3
V
V
OM +
Maximum positive peak output
voltage swing
R 10 kΩ
Full range 13.7 13.8 13.9
V
V
Maximum ne
g
ative peak output
R
L
= 10 kΩ
25°C 13.7 14.1 13.7 14.1 13.7 14.1
V
V
OM
Maximum negative peak output
voltage swing
Full range 13.6 13.6 13.6
V
A
Lar
g
e-si
g
nal differential
V ± 10 V
R 10 kΩ
25°C 0.4 2 0.8 4 1 7
V/ V
A
VD
Large signal differential
voltage amplification
V
O
= ±10 V, R
L
= 10 kΩ
Full range
0.4 0.8 1
V/μV
CMRR
Common mode rejection ratio
V V min
R 50 Ω
25°C 92 102 94 105 97 108
dB
CMRR Common-mode rejection ratio V
IC
= V
ICR
min, R
S
= 50 Ω
Full range
88 90 93
dB
k
Su
pp
l
y
-volta
g
e re
j
ection ratio
V ± 2 5 V to ±15 V
25°C 98 112 100 115 103 117
dB
k
SVR
Supply voltage rejection ratio
(ΔV
CC
±
/ΔV
IO
)
V
CC
±
= ± 2.5 V to ±15 V
Full range 93 95 98
dB
I
Supply current
25°C 1050 1400 1050 1400 1050 1400
A
I
CC
Supply current
V
O
= 0
No load
Full range 1400 1400 1400
μA
ΔI
Suppl
y
current chan
g
e over
V
O
=
0
,
N
o
l
oa
d
Full range
20
20
20
μA
Δ
I
CC
Supply current change over
operating temperature range
Full range 20 20 20 μA
Full range is 0°C to 70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at T