SLCS115D − DECEMBER 1986 − REVISED JULY 2003
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
POST OFFICE BOX 1443
• HOUSTON, TEXAS 77251−1443
recommended operating conditions
TLC393I
UNIT
MIN NOM MAX
UNIT
Supply voltage, V
DD
3 5 16 V
Common-mode input voltage, V
IC
− 0.2 V
DD
− 1.5 V
Low-level output current, I
OL
20 mA
Operating free-air temperature, T
A
− 40 85 °C
electrical characteristics at specified operating free-air temperature, V
DD
= 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
†
T
TLC393I
UNIT
PARAMETER
TEST CONDITIONS
†
T
A
MIN TYP MAX
UNIT
V
Inp t offset oltage
V
IC
= V
ICR
min,
V
DD
5Vto10V
25°C 1.4 5
mV
V
IO
Input offset voltage
V
DD
= 5 V to 10 V,
See Note 3
−40°C to 85°C 7
mV
I
Inp t offset c rrent
V 25V
25°C 1 pA
I
IO
Input offset current V
IC
= 2.5 V
85°C 1 nA
I
Inp t bias c rrent
V 25V
25°C 5 pA
I
IB
Input bias current V
IC
= 2.5 V
85°C 2 nA
V
Common mode inp t oltage range
25°C 0 to V
DD
− 1
V
V
ICR
Common-mode input voltage range
−40°C to 85°C 0 to V
DD
− 1.5
V
25°C 84
CMMR Common-mode rejection ratio V
IC
= V
ICR
min
85°C 84
dB
CMMR
Common mode
rejection
ratio
V
IC
V
ICR
min
− 40°C 84
dB
25°C 85
k
SVR
Supply-voltage rejection ratio V
DD
= 5 V to 10 V
85°C 85
dB
k
SVR
Su ly voltage
rejection
ratio
V
DD
5
V
to
10
V
− 40°C 84
dB
V
Lo le el o tp t oltage
V 1V I 6mA
25°C 300 400
mV
V
OL
Low-level output voltage V
ID
= −1 V, I
OL
= 6 mA
85°C 700
mV
I
High le el o tp t c rrent
V1VV5V
25°C 0.8 40 nA
I
OH
High-level output current V
ID
= 1 V, V
O
= 5 V
85°C 1 µA
I
DD
Su
pp
ly current (both com
p
arators)
Out
p
uts low No load
25°C 22 40
µA
I
DD
Supply current (both comparators) Outputs low, No load
−40°C to 85°C 65
µA
†
All characteristics are measured with zero common-mode voltage unless otherwise noted.
NOTE 3: The offset voltage limits given are the maximum values required to drive the output up to 4.5 V or down to 0.3 V.