Datasheet

   
    
SLOS051E − OCTOBER 1987 − REVISED AUGUST 2008
9
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics at specified free-air temperature, V
DD
= 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLC27M2M
TLC27M7M
UNIT
PARAMETER
TEST CONDITIONS
MIN TYP MAX
UNIT
TLC27M2M
V
O
= 1.4 V,
V
IC
= 0,
25°C 1.1 10
V
IO
Input offset voltage
TLC27M2M
V
O
= 1.4 V,
R
S
= 50 ,
V
IC
= 0,
R
L
= 100 k
Full range
12
mV
V
IO
Input offset voltage
TLC27M7M
V
O
= 1.4 V,
V
IC
= 0,
25°C 185 500
mV
TLC27M7M
V
O
= 1.4 V,
R
S
= 50 ,
V
IC
= 0,
R
L
= 100 k
Full range
3750
α
VIO
Average temperature coefficient of input
offset voltage
25°C to
125°C
1.7 µV/°C
I
IO
Input offset current (see Note 4)
V
O
= 2.5 V,
V
IC
= 2.5 V
25°C 0.1 60 pA
I
IO
Input offset current (see Note 4) V
O
= 2.5 V, V
IC
= 2.5 V
125°C
1.4 15 nA
I
IB
Input bias current (see Note 4)
V
O
= 2.5 V,
V
IC
= 2.5 V
25°C 0.6 60 pA
I
IB
Input bias current (see Note 4) V
O
= 2.5 V, V
IC
= 2.5 V
125°C
9 35 nA
V
ICR
Common-mode input voltage range
25°C
0
to
4
0.3
to
4.2
V
V
ICR
Common-mode input voltage range
(see Note 5)
Full range
0
to
3.5
V
25°C 3.2 3.9
V
OH
High-level output voltage V
ID
= 100 mV, R
L
= 100 k
−55°C
3 3.9
V
V
OH
High-level output voltage
V
ID
= 100 mV,
R
L
= 100 k
125°C 3 4
V
25°C 0 50
V
OL
Low-level output voltage V
ID
= −100 mV, I
OL
= 0
−55°C
0 50
mV
V
OL
Low-level output voltage
V
ID
= −100 mV,
I
OL
= 0
125°C 0 50
mV
Large-signal differential voltage
25°C 25 170
A
VD
Large-signal differential voltage
amplification
V
O
= 0.25 V to 2 V
,
R
L
= 100 k
−55°C
15 290
V/mV
A
VD
amplification
V
O
= 0.25 V to 2 V,
R
L
= 100 k
125°C 15 120
V/mV
25°C 65 91
CMRR Common-mode rejection ratio V
IC
= V
ICR
min
−55°C 60 89
dB
CMRR
Common-mode rejection ratio
V
IC
= V
ICR
min
125°C 60 91
dB
Supply-voltage rejection ratio
25°C 70 93
k
SVR
Supply-voltage rejection ratio
(V
DD
/V
IO
)
V
DD
= 5 V to 10 V, V
O
= 1.4 V
−55°C
60 91
dB
k
SVR
(V
DD
/V
IO
)
V
DD
= 5 V to 10 V,
V
O
= 1.4 V
125°C 60 94
dB
V
O
= 2.5 V,
V
IC
= 2.5 V,
25°C 210 560
I
DD
Supply current (two amplifiers)
V
O
= 2.5 V,
No load
V
IC
= 2.5 V,
−55°C
340 880
µA
I
DD
Supply current (two amplifiers)
No load
125°C 140 360
µA
Full range is −55°C to 125°C.
NOTES: 4. The typical values of input bias current and input offset current below 5 pA were determined mathematically.
5. This range also applies to each input individually.