Datasheet
TLC271, TLC271A, TLC271B
LinCMOS PROGRAMMABLE LOW-POWER
OPERATIONAL AMPLIFIERS
SLOS090D – NOVEMBER 1987 – REVISED MARCH 2001
15
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
TYPICAL CHARACTERISTICS (HIGH-BIAS MODE)
†
Figure 10
0
300
VOL – Low-Level Output Voltage – mV
V
IC
– Common-Mode Input Voltage – V
4
700
1 2 3
400
500
600
T
A
= 25°C
I
OL
= 5 mA
V
DD
= 5 V
V
ID
= –1 V
LOW-LEVEL OUTPUT VOLTAGE
vs
COMMON-MODE INPUT VOLTAGE
650
550
450
350
V
OL
V
ID
= –100 mV
Figure 11
250
0
V
IC
– Common-Mode Input Voltage – V
300
350
400
450
500
246810
V
DD
= 10 V
I
OL
= 5 mA
T
A
= 25°C
V
ID
= –1 V
V
ID
= –2.5 V
V
ID
= –100 mV
LOW-LEVEL OUTPUT VOLTAGE
vs
COMMON-MODE INPUT VOLTAGE
13579
VOL – Low-Level Output Voltage – mV
V
OL
Figure 12
0
V
ID
– Differential Input Voltage – V
– 10– 2 – 4 – 6 – 8
800
700
600
500
400
300
200
100
0
I
OL
= 5 mA
V
IC
= V
ID
/2
T
A
= 25°C
V
DD
= 10 V
LOW-LEVEL OUTPUT VOLTAGE
vs
DIFFERENTIAL INPUT VOLTAGE
VOL – Low-Level Output Voltage – mV
V
OL
– 1 – 3 – 5 – 7 – 9
V
DD
= 5 V
Figure 13
– 75
0
T
A
– Free-Air Temperature – °C
125
900
– 50 – 25 0 25 50 75 100
100
200
300
400
500
600
700
800
V
IC
= 0.5 V
V
ID
= –1 V
I
OL
= 5 mA
LOW-LEVEL OUTPUT VOLTAGE
vs
FREE-AIR TEMPERATURE
VOL – Low-Level Output Voltage – mV
V
OL
V
DD
= 10 V
V
DD
= 5 V
†
Data at high and low temperatures are applicable only within the rated operating free-air temperature ranges of the various devices.