Datasheet
Table Of Contents
- FEATURES
- DESCRIPTION
- ABSOLUTE MAXIMUM RATINGS
- DISSIPATION RATINGS
- RECOMMENDED OPERATING CONDITIONS
- TLC2272Q ELECTRICAL CHARACTERISTICS
- TLC2272Q OPERATING CHARACTERISTICS
- TLC2272Q ELECTRICAL CHARACTERISTICS
- TLC2272Q OPERATING CHARACTERISTICS
- TLC2274Q ELECTRICAL CHARACTERISTICS
- TLC2274Q OPERATING CHARACTERISTICS
- TLC2274Q ELECTRICAL CHARACTERISTICS
- TLC2274Q OPERATING CHARACTERISTICS
- TYPICAL CHARACTERISTICS
- APPLICATION INFORMATION
- REVISION HISTORY
TLC2272-Q1 , TLC2272A-Q1
TLC2274-Q1, TLC2274A-Q1
www.ti.com
SGLS007E –FEBRUARY 2003– REVISED JANUARY 2012
Actual Device Component Count
(1)
COMPONENT TLC2272 TLC2274
Transistors 38 76
Resistors 26 52
Diodes 9 18
Capacitors 3 6
(1) Includes both amplifiers and all ESD, bias, and trim circuitry
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
VALUE UNIT
V
DD+
Supply voltage
(2)
8 V
V
DD−
Supply voltage
(2)
−8 V
V
ID
Differential input voltage
(3)
±16 V
V
I
Input voltage range
(2)
Any input V
DD−
− 0.3 to V
DD+
V
I
I
Input current Any input ±5 mA
I
O
Output current ±50 mA
Total current into V
DD+
±50 mA
Total current out of V
DD−
±50 mA
Duration of short-circuit current at (or below) 25°C
(4)
unlimited
Continuous total dissipation See Dissipation Ratings
T
A
Operating free-air temperature range -40°C to 125°C °C
T
stg
Storage temperature range −65 to 150 °C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds D or PW package 260 °C
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential voltages, are with respect to the midpoint between V
DD+
and V
DD −
.
(3) Differential voltages are at I
N+
with respect to I
N −
. Excessive current will flow if input is brought below V
DD−
− 0.3 V.
(4) The output may be shorted to either supply. Temperature and/or supply voltages must be limited to ensure that the maximum dissipation
rating is not exceeded.
DISSIPATION RATINGS
DERATING
T
A
≤ 25°C T
A
= 70°C T
A
= 85°C T
A
= 125°C
PACKAGE FACTOR
POWER RATING POWER RATING POWER RATING POWER RATING
ABOVE T
A
= 25°C
D-8 725 mW 5.8 mW/°C 464 mW 337 mW 145 mW
D-14 950 mW 7.6 mW/°C 608 mW 494 mW 190 mW
D-14 525 mW 4.2 mW/°C 336 mW 273 mW 105 mW
D-14 700 mW 5.6 mW/°C 448 mW 364 mW -
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
DD±
Supply voltage ±2.2 ±8 V
V
I
Input voltage V
DD−
V
DD+
−1.5 V
V
IC
Common-mode input voltage V
DD−
V
DD+
−1.5 V
T
A
Operating free-air temperature −40 125 °C
Copyright © 2003–2012, Texas Instruments Incorporated Submit Documentation Feedback 3