Datasheet

   
   
 
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
40
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
TLC2201Y electrical characteristics at V
DD±
= ±5 V, T
A
= 25°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLC2201Y
UNIT
PARAMETER
TEST CONDITIONS
MIN TYP MAX
UNIT
V
IO
Input offset voltage 100 µV
Input offset voltage long-term drift (see Note 4)
V
IC
= 0,
R
S
= 50
0.001 µV/mo
I
IO
Input offset current
V
IC
= 0, R
S
= 50
0.5 pA
I
IB
Input bias current 1 pA
V
OH
Maximum high-level output voltage R
L
= 10 k 4.8 V
V
OL
Maximum low-level output voltage I
O
= 0 0 mV
A
VD
Large-signal differential voltage amplification
V
O
= 1 V to 4 V, R
L
= 500 55
V/mV
A
VD
Large-signal differential voltage amplification
V
O
= 1 V to 4 V,
R
L
= 10 55
V/mV
CMRR Common-mode rejection ratio
V
IC
= V
ICR
min,
R
S
= 50
V
O
= 0,
110 dB
k
SVR
Supply voltage rejection ratio (V
DD±
/V
IO
) V
DD
= 4.6 to 16 V 110 dB
I
DD
Supply current per amplifier V
O
= 2.5 V, No load 1 mA
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at T
A
= 150°C extrapolated
to T
A
= 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2201Y operating characteristics at V
DD
±
= ± 5 V, T
A
= 25°C
PARAMETER
TEST CONDITIONS
TLC2201Y
UNIT
PARAMETER
TEST CONDITIONS
MIN TYP MAX
UNIT
SR Positive slew rate at unity gain V
O
= ±0.5 to 2.5 V, R
L
= 10 k, C
L
= 100 pF 2.5 V/µs
V
n
Equivalent input noise voltage
f = 10 Hz 18
nV/Hz
V
n
Equivalent input noise voltage
f = 1 kHz
8
nV/Hz
V
N(PP)
Peak-to-peak equivalent input noise
f = 0.1 to 1 Hz 0.5
V
V
N(PP)
Peak-to-peak equivalent input noise
voltage
f = 0.1 to 10 Hz
0.7
µV
I
n
Equivalent input noise current 0.6 pA/Hz
Gain-bandwidth product f = 10 kHz, R
L
= 10 k, C
L
= 100 pF 1.8 MHz
φ
m
Phase margin at unity gain R
L
= 10 k, C
L
= 100 pF 48°