Datasheet

   
   
 
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
28
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
TLC2201M electrical characteristics at specified free-air temperature, V
DD ±
= ±5 V (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
T
A
TLC2201M
UNIT
PARAMETER
TEST CONDITIONS
T
A
MIN TYP MAX
UNIT
V
IO
Input offset voltage
25°C 100 500
V
V
IO
Input offset voltage
Full range 700
µV
α
VIO
Temperature coefficient of input offset voltage Full range 0.5 µV/°C
Input offset voltage long-term drift (see Note 4)
V
IC
= 0,
R
S
= 50
25°C 0.001 0.005 µV/mo
I
IO
Input offset current
V
IC
= 0, R
S
= 50
25°C
0.5 60
pA
I
IO
Input offset current
Full range 500
pA
I
IB
Input bias current
25°C 1 60
pA
I
IB
Input bias current
Full range 500
pA
−5
V
ICR
Common-mode input voltage range
R
S
= 50
Full range
−5
to
V
V
ICR
Common-mode input voltage range
R
S
= 50
Full range
to
2.7
V
V
OM+
Maximum positive peak output voltage swing
25°C 4.7 4.8
V
V
OM+
Maximum positive peak output voltage swing
R
L
= 10 k
Full range 4.7
V
V
OM
Maximum negative peak output voltage swing
R
L
= 10 k
25°C 4.7 4.9
V
V
OM
Maximum negative peak output voltage swing
Full range 4.7
V
V
O
= ±4 V,
R
L
= 500 k
25°C 400 560
A
VD
Large-signal differential voltage amplification
V
O
= ±4 V, R
L
= 500 k
Full range
200
V/mV
A
VD
Large-signal differential voltage amplification
V
O
= ±4 V,
R
L
= 10 k
25°C 90 100
V/mV
V
O
= ±4 V, R
L
= 10 k
Full range
45
CMRR
Common-mode rejection ratio
V
IC
= V
ICR
min, 25°C 90 115
dB
CMRR Common-mode rejection ratio
V
O
= 0,
R
S
= 50 Full range 85
dB
k
SVR
Supply voltage rejection ratio (V
DD
/V
IO
)
V
DD
= ±2.3 V to ±8 V
25°C 90 110
dB
k
SVR
Supply voltage rejection ratio (V
DD±
/V
IO
)V
DD±
= ±2.3 V to ±8 V
Full range 85
dB
I
DD
Supply current
V
O
= 0,
No load
25°C 1.1 1.5
mA
I
DD
Supply current
V
O
= 0,
No load
Full range 1.5
mA
Full range is −55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at T
A
= 150°C extrapolated
to T
A
= 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
TLC2201M operating characteristics at specified free-air temperature, V
DD±
= ±5 V
PARAMETER
TEST CONDITIONS
T
A
TLC2201M
UNIT
PARAMETER
TEST CONDITIONS
T
A
MIN TYP MAX
UNIT
SR
Slew rate at unity gain
V
O
= ±2.3 V,
C = 100 pF
R
L
= 10 k,
25°C 2 2.7
V/ s
SR Slew rate at unity gain
V
O
= 2.3 V,
C
L
= 100 pF
R
L
= 10 k ,
Full range 1.3
V/µs
V
n
Equivalent input noise voltage
f = 10 Hz 25°C 18
nV/Hz
V
n
Equivalent input noise voltage
f = 1 kHz
25°C 8
nV/Hz
V
N(PP)
Peak-to-peak equivalent input noise voltage
f = 0.1 to 1 Hz 25°C 0.5
V
V
N(PP)
Peak-to-peak equivalent input noise voltage
f = 0.1 to 10 Hz
25°C 0.7
µV
I
n
Equivalent input noise current 25°C 0.6 fA/Hz
Gain-bandwidth product
f = 10 kHz,
C = 100 pF
R
L
= 10 k,
25°C
1.9
MHz
Gain-bandwidth product
f = 10 kHz,
C
L
= 100 pF
R
L
= 10 k,
25°C 1.9 MHz
φ
m
Phase margin R
L
= 10 k, C
L
= 100 pF 25°C 48°