Datasheet

   
   
 
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
29
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
TLC2201M electrical characteristics at specified free-air temperature, V
DD±
= ±5 V (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
T
A
TLC2201AM TLC2201BM
UNIT
PARAMETER
TEST CONDITIONS
T
A
MIN TYP MAX MIN TYP MAX
UNIT
V
IO
Input offset voltage
25°C 80 200 80 200
V
V
IO
Input offset voltage
Full range 400 400
µV
VIO
Temperature coefficient of
Full range
0.5
0.5
V/°C
α
VIO
Temperature coefficient of
input offset voltage
Full range 0.5 0.5 µV/°C
Input offset voltage
long-term drift (see Note 4)
V
IC
= 0, R
S
= 50
25°C
0.001 0.005 0.001 0.005 µV/mo
I
IO
Input offset current
25°C 0.5 60 0.5 60
pA
I
IO
Input offset current
Full range 500 500
pA
I
IB
Input bias current
25°C 1 60 1 60
pA
I
IB
Input bias current
Full range 500 500
pA
Common-mode input
−5
−5
V
ICR
Common-mode input
voltage range
R
S
= 50
Full range
−5
to
−5
to
V
V
ICR
voltage range
R
S
= 50
Full range
to
2.7
to
2.7
V
V
OM+
Maximum positive peak
25°C 4.7 4.8 4.7 4.8
V
V
OM+
Maximum positive peak
output voltage swing
R
L
= 10 k
Full range 4.7 4.7
V
V
OM
Maximum negative peak
R
L
= 10 k
25°C 4.7 4.9 4.7 4.9
V
V
OM
Maximum negative peak
output voltage swing
Full range 4.7 4.7
V
V
O
=
±
4 V,
25°C 400 560 400 560
A
VD
Large-signal differential
V
O
= ±4 V,
R
L
= 500 k
Full range 200 200
V/mV
A
VD
Large-signal differential
voltage amplification
V
O
=
±
4 V,
25°C 90 100 90 100
V/mV
voltage amplification
V
O
= ±4 V,
R
L
= 10 k
Full range 45 45
CMRR
Common-mode rejection
V
IC
= V
ICR
min, 25°C 90 115 90 115
dB
CMRR
Common-mode rejection
ratio
V
O
= 0,
R
S
= 50 Full range 85 85
dB
k
SVR
Supply voltage rejection
V
DD
= ±2.3 V to ±8 V
25°C 90 110 90 110
dB
k
SVR
Supply voltage rejection
ratio (V
DD±
/V
IO
)
V
DD ±
= ±2.3 V to ±8 V
Full range 85 85
dB
I
DD
Supply current
V
O
= 0,
No load
25°C 1.1 1.5 1.1 1.5
mA
I
DD
Supply current
V
O
= 0,
No load
Full range 1.5 1.5
mA
Full range is −55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observable through 168 hours of operating life test at T
A
= 150°C extrapolated
to T
A
= 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.