Datasheet

   
   
 
SLOS175B − FEBRUARY 1997 − REVISED JANUARY 2008
10
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
TLC2201C operating characteristics at specified free-air temperature, V
DD±
= ±5 V
PARAMETER
TEST CONDITIONS
T
A
TLC2201AC TLC2201BC
UNIT
PARAMETER
TEST CONDITIONS
T
A
MIN TYP MAX MIN TYP MAX
UNIT
SR
Slew rate at unity gain
V
O
=
±
2.3 V,
R
L
= 10 k
,
25°C 2 2.7 2 2.7
V/ s
SR Slew rate at unity gain
V
O
= ±2.3 V,
C
L
= 100 pF
R
L
= 10 k ,
Full range 1.5 1.5
V/µs
V
n
Equivalent input noise volt-
f = 10 Hz 25°C 18 35 18 30
nV/Hz
V
n
Equivalent input noise volt-
age (see Note 5)
f = 1 kHz
25°C 8 15 8 12
nV/Hz
V
N(PP)
Peak-to-peak equivalent input
f = 0.1 to 1 Hz 25°C 0.5 0.5
V
V
N(PP
)
Peak-to-peak equivalent input
noise voltage
f = 0.1 to 10 Hz
25°C 0.7 0.7
µV
I
n
Equivalent input noise current 25°C 0.6 0.6
fA/Hz
Gain-bandwidth product
f = 10 kHz,
R
L
= 10 kΩ,
25°C
1.9
1.9
MHz
Gain-bandwidth product
f = 10 kHz,
C
L
= 100 pF
R
L
= 10 kΩ,
25°C 1.9 1.9 MHz
φ
m
Phase margin at unity gain R
L
= 10 k, C
L
= 100 pF 25°C 48° 48°
Full range is 0°C to +70°C.
NOTE 5: This parameter is tested on a sample basis for the TLC2201A and on all devices for the TLC2201B. For other test requirements, please