absolute maximum ratings over operating junction temperature range (unless otherwise noted)
Continuous input voltage 26 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transient input voltage, T
A
= 25°C (see Note 1) 60 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous reverse input voltage −15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transient reverse input voltage, t 100 ms −50 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature, T
J
150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) for 10 seconds 260 °C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The transient input voltage rating applies to the waveform shown in Figure 1.
package thermal data (see Note 2)
PACKAGE BOARD θ
JC
θ
JA
PDIP (P) High K, JESD 51-7 57°C/W 85°C/W
POWER-FLEX (KTE) High K, JESD 51-5 3°C/W 23°C/W
SOIC (D) High K, JESD 51-7 39°C/W 97°C/W
TO-226 / TO-92 (LP) High K, JESD 51-7 55°C/W 140°C/W
TO-220 (KC) High K, JESD 51-5 3°C/W 19°C/W
NOTE 2: Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) − T
A
)/θ
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
recommended operating conditions over recommended operating junction temperature range
(unless otherwise noted)
MIN MAX UNITS
TL75xL05 6 26
V
I
TL75xL08 9 26
V
V
I
Input voltage
TL75xL10
11 26
V
TL75xL12 13 26
V
IH
High-level ENABLE input voltage
TL751Lxx 2 15 V
V
IL
Low-level ENABLE input voltage
T
J
= 25°C TL751Lxx −0.3 0.8
V
V
IL
Low-level ENABLE input voltage
T
J
= 0°C to 125°C
TL751Lxx −0.15 0.8
V
I
O
Output current range TL75xLxx 0 150 mA
T
J
Operating virtual junction temperature TL75xLxxC 0 125 °C
The algebraic convention, in which the least positive (most negative) value is designated minimum, is used in this data sheet for ENABLE
voltage
levels and temperature only.