TL4050x10Q ELECTRICAL CHARACTERISTICS
DV
Z
DI
Z
TL4050
www.ti.com
........................................................................................................................................................ SLOS486A – JUNE 2007 – REVISED AUGUST 2009
at extended temperature range, full range T
A
= – 40 ° C to 125 ° C (unless otherwise noted)
TL4050A10Q TL4050B10Q TL4050C10Q
PARAMETER TEST CONDITIONS T
A
UNIT
MIN TYP MAX MIN TYP MAX MIN TYP MAX
Reverse
V
Z
breakdown I
Z
= 100 µ A 25 ° C 10 10 10 V
voltage
25 ° C – 10 10 – 20 20 – 50 50
Reverse
Δ V
Z
breakdown I
Z
= 100 µ A mV
Full
– 60 60 – 70 70 – 100 100
voltage tolerance
range
25 ° C 80 100 80 100 80 100
Minimum
I
Z,min
µ A
Full
cathode current
110 110 110
range
I
Z
= 10 mA 25 ° C ± 40 ± 40 ± 40
Average
temperature
I
Z
= 1 mA 25 ° C ± 20 ± 20 ± 20
coefficient of
α
VZ
ppm/ ° C
25 ° C ± 20 ± 20 ± 20
reverse
breakdown
I
Z
= 100 µ A
Full
± 50 ± 50 ± 50
voltage
range
25 ° C 0.8 1.5 0.8 1.5 0.8 1.5
I
Z,min
< I
Z
< 1 mA
Reverse
Full
3.5 3.5 3.5
breakdown
range
voltage change mV
25 ° C 8 12 8 12 8 12
with cathode
current change
1 mA < I
Z
< 15 mA
Full
23 23 23
range
I
Z
= 1 mA,
Reverse dynamic
Z
Z
f = 120 Hz, 25 ° C 0.7 0.7 0.7 Ω
impedance
I
AC
= 0.1 I
Z
I
Z
= 100 µ A,
e
N
Wideband noise 25 ° C 150 150 150 µ V
RMS
10 Hz ≤ f ≤ 10 kHz
Long-term
stability of t = 1000 h,
reverse T
A
= 25 ° C ± 0.1 ° C, 120 120 120 ppm
breakdown I
Z
= 100 µ A
voltage
Thermal
V
HYST
Δ T
A
= – 40 ° C to 125 ° C 2.8 2.8 2.8 mV
hysteresis
(1)
(1) Thermal hysteresis is defined as V
Z,25 ° C
(after cycling to – 40 ° C) – V
Z,25 ° C
(after cycling to 125 ° C).
Copyright © 2007 – 2009, Texas Instruments Incorporated Submit Documentation Feedback 13
Product Folder Link(s): TL4050