POST OFFICE BOX 655303 DALLAS, TEXAS 75265
recommended operating conditions (see Note 3)
SN54S04
SN74S04
SN54S04
SN74S04
UNIT
MIN NOM MAX MIN NOM MAX
UNIT
V
CC
Supply voltage 4.5 5 5.5 4.75 5 5.25 V
V
IH
High-level input voltage 2 2 V
V
IL
Low-level input voltage 0.8 0.8 V
I
OH
High-level output current −1 −1 mA
I
OL
Low-level output current 20 20 mA
T
A
Operating free-air temperature −55 125 0 70 °C
NOTE 3: All unused inputs of the device must be held at V
CC
or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
SN54S04 SN74S04
UNIT
PARAMETER
TEST CONDITIONS
MIN TYP
MAX MIN TYP
MAX
UNIT
V
IK
V
CC
= MIN, I
I
= −18 mA 1.2 1.2 V
V
OH
V
CC
= MIN, V
IL
= 0.8 V, I
OH
= −1 mA 2.5 3.4 2.7 3.4 V
V
OL
V
CC
= MIN, V
IH
= 2 V, I
OL
= 20 mA 0.5 0.5 V
I
I
V
CC
= MAX, V
I
= 5.5 V 1 1 mA
I
IH
V
CC
= MAX, V
I
= 2.7 V 50 50 µA
I
IL
V
CC
= MAX, V
I
= 0.5 V −2 −2 mA
I
OS
§
V
CC
= MAX −40 −100 −40 −100 mA
I
CCH
V
CC
= MAX, V
I
= 0 V 15 24 15 24 mA
I
CCL
V
CC
= MAX, V
I
= 4.5 V 30 54 30 54 mA
For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
All typical values are at V
CC
= 5 V, T
A
= 25°C.
§
Not more than one output should be shorted at a time, and the duration of the short-circuit should not exceed one second.
switching characteristics, V
CC
= 5 V, T
A
= 25°C (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TEST CONDITIONS
SN54S04
SN74S04
UNIT
PARAMETER
(INPUT)
(OUTPUT)
TEST CONDITIONS
MIN TYP MAX
UNIT
t
PLH
A
Y
R
L
= 280 ,
C
L
= 15 pF
3 4.5
ns
t
PHL
A
Y
R
L
= 280
,
C
L
= 15 pF
3 5
ns
t
PLH
A
Y
R
L
= 280 ,
C
L
= 50 pF
4.5
ns
t
PHL
A
Y
R
L
= 280
,
C
L
= 50 pF
5
ns