Datasheet

www.ti.com
Switching Characteristics
Operating Characteristics
SN74LVCU04A
HEX INVERTER
SCAS282M JANUARY 1993 REVISED FEBRUARY 2005
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1 )
V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 3.3 V
V
CC
= 2.7 V
FROM TO
± 0.15 V ± 0.2 V ± 0.3 V
PARAMETER UNIT
(INPUT) (OUTPUT)
MIN MAX MIN MAX MIN MAX MIN MAX
t
pd
A Y 1 7.3 1 6.7 1 4.7 1 3.8 ns
t
sk(o)
1 ns
T
A
= 25 ° C
V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 3.3 V
TEST
PARAMETER UNIT
CONDITIONS
TYP TYP TYP
C
pd
Power dissipation capacitance per inverter f = 10 MHz 3 4 5 pF
4