Datasheet

SN74LVC1G32
www.ti.com
SCES219S APRIL 1999REVISED JULY 2013
Switching Characteristics
(1)
over recommended operating free-air temperature range, C
L
= 30 pF or 50 pF (unless otherwise noted) (see Figure 2)
–40°C to 125°C –40°C to 125°C
–40°C to 85°C –40°C to 85°C
Recommended Recommended
FROM TO
PARAMETER UNIT
V
CC
= 3.3 V V
CC
= 3.3 V V
CC
= 5 V V
CC
= 5 V
(INPUT) (OUTPUT)
± 0.3 V ± 0.3 V ± 0.5 V ± 0.5 V
MIN MAX MIN MAX MIN MAX MIN MAX
t
pd
A or B Y 1.1 4.5 1 4 1 4 1 4.5 ns
(1) On products compliant to MIL-PRF-38535, this parameter is not production tested
Operating Characteristics
T
A
= 25°C
V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 3.3 V V
CC
= 5 V
TEST
PARAMETER UNIT
CONDITIONS
TYP TYP TYP TYP
C
pd
Power dissipation capacitance f = 10 MHz 20 20 21 22 pF
Copyright © 1999–2013, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: SN74LVC1G32