ELECTRICAL CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
–40°C to 125°C
–40°C to 85°C
PARAMETER TEST CONDITIONS V
CC
Recommended UNIT
MIN TYP
(1)
MAX MIN TYP MAX
I
OH
= –100 μA 1.65 V to 5.5 V V
CC
0.1 V
CC
0.15
I
OH
= –4 mA 1.65 V 1.2 1.2
I
OH
= –8 mA 2.3 V 1.9 1.9
V
OH
V
I
OH
= –16 mA 2.4 2.4
3 V
I
OH
= –24 mA 2.3 2.3
I
OH
= –32 mA 4.5 V 3.8 3.8
I
OL
= 100 μA 1.65 V to 5.5 V 0.1 0.1
I
OL
= 4 mA 1.65 V 0.45 0.45
I
OL
= 8 mA 2.3 V 0.3 0.3
V
OL
V
I
OL
= 16 mA 0.4 0.4
3 V
I
OL
= 24 mA 0.55 0.55
I
OL
= 32 mA 4.5 V 0.55 0.55
A or B
I
I
V
I
= 5.5 V or GND 0 to 5.5 V ±5 ±5 μA
inputs
I
off
V
I
or V
O
= 5.5 V 0 ±10 ±10 μA
V
I
= 5.5 V or
I
CC
I
O
= 0 1.65 V to 5.5 V 10 10 μA
GND,
One input at Other inputs at
ΔI
CC
3 V to 5.5 V 500 500 μA
V
CC
0.6 V, V
CC
or GND
C
i
V
I
= V
CC
or GND 3.3 V 4 4 pF
(1) All typical values are at V
CC
= 3.3 V, T
A
= 25°C.
SWITCHING CHARACTERISTICS
over recommended operating free-air temperature range, C
L
= 15 pF (unless otherwise noted) (see Figure 1)
SN74LVC1G08
–40°C to 85°C
FROM TO
PARAMETER UNIT
V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 3.3 V V
CC
= 5 V
(INPUT) (OUTPUT)
± 0.15 V ± 0.2 V ± 0.3 V ± 0.5 V
MIN MAX MIN MAX MIN MAX MIN MAX
t
pd
A or B Y 1.5 7.2 0.7 4.4 0.8 3.6 0.8 3.4 ns
SWITCHING CHARACTERISTICS
(1)
over recommended operating free-air temperature range, C
L
= 30 pF or 50 pF (unless otherwise noted) (see Figure 2)
–40°C to 125°C –40°C to 125°C
–40°C to 85°C –40°C to 85°C
Recommended Recommended
FROM TO
PARAMETER UNIT
V
CC
= 1.8 V V
CC
= 1.8 V V
CC
= 2.5 V V
CC
= 2.5 V
(INPUT) (OUTPUT)
± 0.15 V ± 0.15 V ± 0.2 V ± 0.2 V
MIN MAX MIN MAX MIN MAX MIN MAX
t
pd
A or B Y 2.4 8 2.4 10 1.1 5.5 1.1 7 ns
(1) On products compliant to MIL-PRF-38535, this parameter is not production tested
4 Submit Documentation Feedback Copyright © 1999–2013, Texas Instruments Incorporated