Datasheet

 
  
  
SCLS450G − DECEMBER 1999 − REVISED APRIL 2005
7
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 2.5 V ± 0.2 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
TEST
T
A
= 25°C SN54LV221A SN74LV221A
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TEST
CONDITIONS
MIN TYP MAX MIN MAX MIN MAX
UNIT
A or B Q or Q
14.6* 31.4* 1* 37* 1 37
t
pd
CLR
Q or Q
C
L
= 15 pF
13.2* 25* 1* 29.5* 1 29.5
ns
t
pd
CLR trigger Q or Q
C
L
= 15 pF
15.2* 33.4* 1* 39* 1 39
ns
A or B Q or Q
16.7 36 1 42 1 42
t
pd
CLR
Q or Q
C
L
= 50 pF
15 32.8 1 34.5 1 34.5
ns
t
pd
CLR trigger Q or Q
C
L
= 50 pF
17.4 38 1 44 1 44
ns
C
L
= 50 pF,
C
ext
= 28 pF,
R
ext
= 2 k
203 260 320 320 ns
t
w
Q or Q
C
L
= 50 pF,
C
ext
= 0.01 µF,
R
ext
= 10 k
90 100 110 90 110 90 110 ms
C
L
= 50 pF,
C
ext
= 0.1 µF,
R
ext
= 10 k
0.9 1 1.1 0.9 1.1 0.9 1.1 ms
t
w
C
L
= 50 pF ±1 %
* On products compliant to MIL-PRF-38535, this parameter is not production tested.
t
w
= Pulse duration at Q and Q
outputs
t
w
= Output pulse-duration variation (Q and Q
) between circuits in same package
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
TEST
T
A
= 25°C SN54LV221A SN74LV221A
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TEST
CONDITIONS
MIN TYP MAX MIN MAX MIN MAX
UNIT
A or B Q or Q
10.2* 20.6* 1* 24* 1 24
t
pd
CLR
Q or Q
C
L
= 15 pF
9.3* 15.8* 1* 18.5* 1 18.5
ns
t
pd
CLR trigger Q or Q
C
L
= 15 pF
10.6* 22.4* 1* 26* 1 26
ns
A or B Q or Q
11.8 24.1 1 27.5 1 27.5
t
pd
CLR
Q or Q
C
L
= 50 pF
10.6 19.3 1 22 1 22
ns
t
pd
CLR trigger Q or Q
C
L
= 50 pF
12.3 25.9 1 29.5 1 29.5
ns
C
L
= 50 pF,
C
ext
= 28 pF,
R
ext
= 2 k
186 240 300 300 ns
t
w
Q or Q
C
L
= 50 pF,
C
ext
= 0.01 µF,
R
ext
= 10 k
90 100 110 90 110 90 110 ms
C
L
= 50 pF,
C
ext
= 0.1 µF,
R
ext
= 10 k
0.9 1 1.1 0.9 1.1 0.9 1.1 ms
t
w
C
L
= 50 pF ±1 %
* On products compliant to MIL-PRF-38535, this parameter is not production tested.
t
w
= Pulse duration at Q and Q
outputs
t
w
= Output pulse-duration variation (Q and Q
) between circuits in same package
  &(!)$'!& "!&"%)& *)!#" & % (!)$'2% !)
%1& *'% !( %2%,!*$%&- ')'"%)" '' '& !%)
*%"("'!& ')% %1& 1!',- %.' &)#$%& )%%)2% % )1 !