Datasheet

SN54HC05, SN74HC05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
SCLS080D – MARCH 1984 – REVISED AUGUST 2003
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
T
A
= 25°C SN54HC05 SN74HC05
PARAMETER
TEST CONDITIONS
V
CC
MIN TYP MAX MIN MAX MIN MAX
I
OH
V
I
= V
IH
or V
IL
, V
O
= V
CC
6 V 0.01 0.5 10 5 µA
V
V = V or V
I = 20 A
2 V 0.002 0.1 0.1 0.1
V
V = V or V
I
OL
= 20
µ
A
4.5 V 0.001 0.1 0.1 0.1
V
OL
V
I
= V
IH
or V
IL
OL
6 V 0.001 0.1 0.1 0.1
OL
IIH IL
I
OL
= 4 mA 4.5 V 0.17 0.26 0.4 0.33
I
OL
= 5.2 mA 6 V 0.15 0.26 0.4 0.33
I
I
V
I
= V
CC
or 0 6 V ±0.1 ±100 ±1000 ±1000 nA
I
CC
V
I
= V
CC
or 0, I
O
= 0 6 V 2 40 20 µA
C
i
2 V to 6 V 3 10 10 10 pF
switching characteristics over recommended operating free-air temperature range, C
L
= 50 pF
(unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
V
CC
T
A
= 25°C SN54HC05 SN74HC05
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
V
CC
MIN TYP MAX MIN MAX MIN MAX
t
A
Y
2 V 60 115 175 145
t
PLH
A
Y
4.5 V 13 23 35 29
PLH
6 V 10 20 30 25
t
A
Y
2 V 45 85 130 105
t
PHL
A
Y
4.5 V 9 17 26 21
PHL
6 V 8 14 22 18
t
Y
2 V 38 75 110 95
t
f
Y
4.5 V 8 15 22 19
f
6 V 6 13 19 16
operating characteristics, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd